| BUILDING OVERVIEW |
Are Feeders Being Installed? : |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
(999) |
OTHER ALL 10 APTS FROM 1 FLOOR TO 14 FLOORCOM: NO ARE FAULT CIRCUIT PROVIDED. 210.12 FOR RECEPTACLE OUTLETS |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 002 |
(999) |
OTHER AND FIXTURES LIVING ROOM AND BEDROOMS |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 003 |
(999) |
OTHER ALL 10 APTS FROM 1 FLOOR TO 14 FLOOR:COM: BATHROOMS: NO APPLIANCE CIRCUIT PROVIDED FOR GFCI. 210.11(C3) |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 004 |
(999) |
OTHER ALL 10 APTS FROM FIRST FLOOR TO 14 FLOORS: 210COM: KITCHEN COUNTER TOP: NO APPLIANCE CIRCUITS PROVIDED |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 005 |
(999) |
OTHER ALL 10 APTS FIRST FLOOR TO 14 FLOORS: 250.52(I)KITCHEN: OUTLETS IS NOT PROVIDED EVERY 4 FL |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 006 |
(999) |
OTHER ALL 10 APTS FROM FIRST FLOOR TO 14 FLOORCOM: KITCHEN RECEPT. OUTLETS, COUNTER TOP NOT ALL RECEPT. ARE GFCI |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 007 |
(999) |
OTHER 210.8(6) |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 008 |
( 46) |
PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY ALL APTS FROM FIRST FLOOR TO 14 FLOORCOM: SUB PANELS NOT PROVIDED DIRECTORY |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 009 |
(999) |
OTHER ALL APTS FROM FIRST FLOOR TO 14 FLOORCOM: ALL RECEPT. OUTLETS AND SWS. LIGHTING FIXS NOT GROUNDED 250.146 |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 010 |
( 3) |
APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE THE ENTIRE BLDG. NEW APTS: SUB PANELS, BRANCH CIRCUIT. PLEASE NOTE(WIRING, RECEPT. OUTLETS, SWS. LIGHTING) |
OPEN |
05/31/2013 |
05/31/2013 |
|
| |
| 011 |
(999) |
OTHER THIS IS NOT A FINAL INSPECTION. SEE THIS COMPLAINT #1349641 |
OPEN |
05/31/2013 |
05/31/2013 |
|