BIS Menu  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M341156
Premises: 221 EAST 63 STREET MANHATTAN BIN: 1043863     Block: 1418   Lot: 11
   

DOB NOW: Inspections


Filed: 225 E 63 ST Census Tract:   110
1 TO 14 FL Admin Area:   M - MANHATTAN Inspection Area:   M
NEW YORK, NY 10065 Community Board:   108
Special Place Name:   10 APTS
DOB Cross Street(s):    3 AVENUE,    2 AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   06/03/2013 Job Start Date:  
Last Change:   08/22/2025 Job End Date:  
Appointment Status:    Complaint Number:    1349641
Last Inspection By:   DORSAINVILLE, R       On     05/31/2013      
Field Disp:   W - ISSUE OBJECTION TO OWNER
Energize Recommendation:  
Objection Disposition:  

License #: Licensee Name: UNKNOWN
Firm: Firm Name: UNKNOWN
Firm Phone:   Firm Address:  

Work Started or Filed by Others: NO
Work Category:    Work To Be Done:   Total Fee:  $0.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: GREENPOINT-GOLDMAN CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 06/03/2013
Power Issued: Response:  

Follow-Up: V - OWNER OBJECTION 06/03/2013
Contractor's Comments:  NONE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M341156
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/31/2013 06/03/2013 RID W (30) (11)
INSPECTION COMMENTS: SEE VIOLATION DETAILS

OBJECTION FOR APPLICATION #: M341156
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
ALL 10 APTS FROM 1 FLOOR TO 14 FLOORCOM: NO ARE FAULT CIRCUIT PROVIDED. 210.12 FOR RECEPTACLE OUTLETS
OPEN 05/31/2013 05/31/2013
 
002 (999) OTHER
AND FIXTURES LIVING ROOM AND BEDROOMS
OPEN 05/31/2013 05/31/2013
 
003 (999) OTHER
ALL 10 APTS FROM 1 FLOOR TO 14 FLOOR:COM: BATHROOMS: NO APPLIANCE CIRCUIT PROVIDED FOR GFCI. 210.11(C3)
OPEN 05/31/2013 05/31/2013
 
004 (999) OTHER
ALL 10 APTS FROM FIRST FLOOR TO 14 FLOORS: 210COM: KITCHEN COUNTER TOP: NO APPLIANCE CIRCUITS PROVIDED
OPEN 05/31/2013 05/31/2013
 
005 (999) OTHER
ALL 10 APTS FIRST FLOOR TO 14 FLOORS: 250.52(I)KITCHEN: OUTLETS IS NOT PROVIDED EVERY 4 FL
OPEN 05/31/2013 05/31/2013
 
006 (999) OTHER
ALL 10 APTS FROM FIRST FLOOR TO 14 FLOORCOM: KITCHEN RECEPT. OUTLETS, COUNTER TOP NOT ALL RECEPT. ARE GFCI
OPEN 05/31/2013 05/31/2013
 
007 (999) OTHER
210.8(6)
OPEN 05/31/2013 05/31/2013
 
008 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
ALL APTS FROM FIRST FLOOR TO 14 FLOORCOM: SUB PANELS NOT PROVIDED DIRECTORY
OPEN 05/31/2013 05/31/2013
 
009 (999) OTHER
ALL APTS FROM FIRST FLOOR TO 14 FLOORCOM: ALL RECEPT. OUTLETS AND SWS. LIGHTING FIXS NOT GROUNDED 250.146
OPEN 05/31/2013 05/31/2013
 
010 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
THE ENTIRE BLDG. NEW APTS: SUB PANELS, BRANCH CIRCUIT. PLEASE NOTE(WIRING, RECEPT. OUTLETS, SWS. LIGHTING)
OPEN 05/31/2013 05/31/2013
 
011 (999) OTHER
THIS IS NOT A FINAL INSPECTION. SEE THIS COMPLAINT #1349641
OPEN 05/31/2013 05/31/2013



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.