Electrical Application Details for App #: M339637
Premises: 5 BEEKMAN STREET MANHATTAN BIN: 1079072     Block: 90   Lot: 14
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 5 BEEKMAN ST Census Tract:   15.01 Health Area:  7700
GROUND FLOOR Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10038 Community Board:   101
DOB Cross Street(s):   THEATER ALLEY,    NASSAU STREET
Status:   C - JOB IS SIGNED OFF 10/22/2018
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  04/25/2013 2:02 PM
Application Entered:   04/25/2013 Job Start Date:   04/26/2013
Last Change:   10/22/2018 Job End Date:   04/10/2014
Appointment Status:   
Last Inspection By:   SCHULER, THOMAS       On     10/20/2018      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011437 Licensee Name: ANTONY GIRONTA
Firm: 002894 Firm Name: AGIR ELEC'L LTD. D/B/A
Firm Phone: 718-846-6200  Firm Address: 130-45 91ST AVENUE PINNACLE ELECTRICAL RICHMOND HILL NY 11418 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
2 - TEMPORARY CONSTRUCTION
9 - OTHER
T - TEMPORARY LIGHT & POWER
Total Fee:  $85.00
Other Work:   HOIST
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ANTONY GIRONTA
Owner Business Name: AGIR/DBA.PINNACLE ELECT.
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WIRING FOR HOIST

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M339637
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/20/2018 10/22/2018 TUR C (10) (0) Y
INSPECTION COMMENTS: TEMPS REMOVED PRIOR TO INSPECTION FOR HOIST