Electrical Application Details for App #: M338155
Premises: 239 EAST 79 STREET MANHATTAN BIN: 1048515     Block: 1525   Lot: 21
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 239 E 79 ST Census Tract:   138 Health Area:  3700
APT 3 F/G Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10075 Community Board:   108
DOB Cross Street(s):    3 AVENUE,    2 AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/19/2013 1:57 PM
Application Entered:   03/19/2013 Job Start Date:   03/19/2013
Last Change:   08/22/2025 Job End Date:   03/19/2014
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   BERGMAN EDUARD       On     09/09/2013      
Field Disp:   A - OBJCTN ISSD: JOB COMPLETE
Energize Recommendation:  
Objection Disposition:  

License #: 010190 Licensee Name: ABE HIMELFARB
Firm: 002663 Firm Name: ALEF ELEC'L CONTR'G INC
Firm Phone: 212-764-2200  Firm Address: 247 WEST 38TH STREET NEW YORK NY 10018 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $49.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: ALLISON ARDEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
003  3F/G  12  15    12             
Buildings Total 12  15    12                
Total Units : 46 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 09/16/2013
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  COMBINE APTS. PANELS ARE EXISTING A/C IS EXISTING

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M338155
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/21/2013 08/28/2013 EDB N (20) (0) Y
INSPECTION COMMENTS: *NO SHOW*
 
(2) 09/09/2013 09/16/2013 EDB A (40) (8) Y
INSPECTION COMMENTS: **SEE OBJECTIONS

OBJECTION FOR APPLICATION #: M338155
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 53) GFCI HAS NOT BEEN PROVIDED
KITCHEN: COUNTER TOP NO G.F.C.I.PROTECTION PROVIDED.. 210.8
OPEN 09/09/2013 09/09/2013
 
002 ( 53) GFCI HAS NOT BEEN PROVIDED
LAUNDRY: G.F.C.I. PROTECTION NOT PROVIDED...... - 210.8
OPEN 09/09/2013 09/09/2013
 
003 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
...3 F/G: NO A.F.C..PROTECTION PROVIDED...... - 210.12
OPEN 09/09/2013 09/09/2013
 
004 (340) RECEPTACLES NOT TAMPERPROOF
3 F/G: NOT EVERY RECEPTACLE TAMPER PROOF...... - 40.6.11
OPEN 09/09/2013 09/09/2013
 
005 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
PANEL: KO MISSING IN THE PANEL
OPEN 09/09/2013 09/09/2013
 
006 ( 63) RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER
3 F/G: MISSING RECEPTACLE IN LIVING ROOM
OPEN 09/09/2013 09/09/2013
 
007 (999) OTHER
KITCHEN: NO OTHER OUTLET(INCLUDING LIGHT)ON SMALL APPLIANCE CKT- 210.52B2
OPEN 09/09/2013 09/09/2013
 
008 ( 19) DEFECTIVE WIRING IS IN USE
PANEL: (OLD) 2 NEUTRAL OR 9 HOTWIRES(NEUTRAL IS OVERLOAD)
OPEN 09/09/2013 09/09/2013