Electrical Application Details for App #: M336008
Premises: 25 COOPER SQUARE MANHATTAN BIN: 1087921     Block: 461   Lot: 1
   
Application Completed and Certified

Filed: 25 COOPER SQUARE Census Tract:   38 Health Area:  6500
CELLAR Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10003 Community Board:   103
Special Place Name:   THE STANDARD
DOB Cross Street(s):   EAST 5 STREET,    EAST 6 STREET
Status:   C - JOB IS SIGNED OFF 01/29/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  01/18/2013 2:17 PM
Application Entered:   01/18/2013 Job Start Date:   01/18/2013
Last Change:   01/29/2014 Job End Date:   01/18/2014
Appointment Status:   
Last Inspection By:   RACEWICZ, TOMASZ       On     12/31/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011818 Licensee Name: CHRISTOPHER F SCHAEFER
Firm: 004289 Firm Name: TRITECH ELECTL & DATA INC
Firm Phone: 718-653-5358  Firm Address: 4288 KATONAH AVENUE BRONX NY 10470 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
6 - GENERAL WIRING
Total Fee:  $40.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: COOPER AB LLC C/O IRONSTA
Authorized Representative:  JAMIE RONGA
Relationship To Owner:   ENTITY OFFICER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL                   
Buildings Total                   
Total Units : 5 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 12/16/2013
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M336008
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/11/2013 12/16/2013 JKF A (30) (4) Y
INSPECTION COMMENTS: NONE
 
(2) 12/31/2013 01/09/2014 TOR C R (20) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M336008
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
SERVICE ROOM: 60 A FUSES FOR 10 AWG TO MOTOR IN KITCHEN AREA MECHCLOSET
RSLV 12/11/2013 12/11/2013 12/31/2013
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
CELLAR KITCHEN: MECHANICAL CLOSET MOTOR DISCONNECT 2 WIRES ON GNDLUG
RSLV 12/11/2013 12/11/2013 12/31/2013
 
003 ( 19) DEFECTIVE WIRING IS IN USE
CELLAR KITCHEN: MECHANICAL CLOSET 2 NEUTRAL WIRES ON ONE TERMINAL INCAR LIGHTS DISCONNECT
RSLV 12/11/2013 12/11/2013 12/31/2013
 
004 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
SERVICE ROOM: PANEL LPB CAR LIGHTS NOT ON DIRECTORY
RSLV 12/11/2013 12/11/2013 12/31/2013