BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M333175
Premises: 42 WEST 13 STREET MANHATTAN BIN: 1009613     Block: 576   Lot: 16
   
Application Completed and Certified

Filed: 42 W 13 ST Census Tract:   63 Health Area:  5700
APT. 5G Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10011 Community Board:   102
DOB Cross Street(s):    5 AVENUE,    AVENUE OF THE AMERICAS
Status:   C - JOB IS SIGNED OFF 08/29/2013
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/17/2012 8:56 AM
Application Entered:   10/17/2012 Job Start Date:   10/17/2012
Last Change:   08/29/2013 Job End Date:   10/16/2013
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     08/26/2013      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011756 Licensee Name: LEONID SIMKIN
Firm: 003366 Firm Name: LENS ELECTRIC, INC
Firm Phone: 646-522-7311  Firm Address: 2802 AVENUE Y BROOKLYN NY 11235 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $109.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: VANESSA&JONATHA O'BRIEN'S
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
005  5G  21  17    10  21     
Buildings Total 21  17    10  21            
Total Units : 76 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 08/12/2013
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M333175
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/06/2013 08/12/2013 GYM A (65) (5) Y
INSPECTION COMMENTS: NONE
 
(2) 08/26/2013 08/29/2013 DAH C R (15) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M333175
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
5FL: NO ARC FAULT PROVIDED BEDROOM A/C LIVING ROOM A/C 210.12
RSLV 08/06/2013 08/06/2013 08/26/2013
 
002 (999) OTHER
5FL: A/C OUTLET IS NOT PROVIDED 210.52 BEDROOM LIVING ROOM
RSLV 08/06/2013 08/06/2013 08/26/2013
 
003 (999) OTHER
5FL: AREA WITH MC CABLE BRANCH WIRING METAL OUTLET BOXES ARE NOTBONDED. 250.146
RSLV 08/06/2013 08/06/2013 08/26/2013
 
004 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
5FL: METAL BOXES MC CABLE WITH ROMEX CONNECTORS
RSLV 08/06/2013 08/06/2013 08/26/2013
 
005 (999) OTHER
5FL: NEW PANEL MULTI CIRCUIT NO BREAKERS TIE PROVIDED 210.4(BREAKERS CAN WINTH WIRES)
RSLV 08/06/2013 08/06/2013 08/26/2013



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back