BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M332367
Premises: 156 PRINCE STREET MANHATTAN BIN: 1007732     Block: 502   Lot: 20
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 156 PRINCE ST Census Tract:   49 Health Area:  6800
1 FLOOR ENTRANCE Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   WEST BROADWAY,    THOMPSON STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/26/2012 11:14 AM
Application Entered:   09/26/2012 Job Start Date:   09/26/2012
Last Change:   08/22/2025 Job End Date:   10/25/2012
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   AGELONIAS, ANASTASIOS       On     05/27/2014      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  
Objection Disposition:  X - NOT REMOVED

License #: 011252 Licensee Name: ALBERT V DATTOLO
Firm: 001211 Firm Name: RAINBOW ELECTRIC CO., INC
Firm Phone: 718-521-0926  Firm Address: 76-18 ROCKAWAY BLVD WOODHAVEN NY 11421 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
3 - ELEVATOR/ESCALATOR/MATERIAL LIFT
Total Fee:  $173.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Commercial/Residential (2  Stores, 14 Apartments)
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MANUEL AGUILIAR
Owner Business Name: JESUS CONST AND GLASS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  30 AMP
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  1  WHEEL CHAIR LIFT
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: C - CALL TO OFFICE 06/05/2014
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  WHEELCHAIR LIFT

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M332367
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/26/2014 03/11/2014 PP1 A (30) (3) Y
INSPECTION COMMENTS: NEED ACCESS TO SUB PANEL
 
(2) 05/27/2014 06/05/2014 IOS H X (10) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M332367
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 19) DEFECTIVE WIRING IS IN USE
TEA STORE: USING #18 ON 20 AMP FUSE
OPEN 02/26/2014 05/27/2014
 
002 ( 19) DEFECTIVE WIRING IS IN USE
TEA STORE: NO NEUTRAL RAN FOR FDR IN DISCONNECT FOR CHAIR LIFT
OPEN 02/26/2014 05/27/2014
 
003 ( 20) PLUG FUSES ARE NOT OF THE TAMPERPROOF TYPE
TEA STORE: GROUND BAR NOT BONDED
OPEN 02/26/2014 05/27/2014



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back