BIS Menu  |  Applications  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M330576
Premises: 74 5 AVENUE MANHATTAN BIN: 1009719     Block: 577   Lot: 42
   
Application Completed and Certified

Filed: 74 5 AV Census Tract:   63 Health Area:  5700
APARTMENT 11A Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10011 Community Board:   102
DOB Cross Street(s):   EAST 13 STREET,    EAST 14 STREET
Status:   C - JOB IS SIGNED OFF 04/26/2014
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/08/2012 9:50 AM
Application Entered:   08/08/2012 Job Start Date:   08/08/2012
Last Change:   04/26/2014 Job End Date:   12/30/2012
Appointment Status:   
Last Inspection By:   SCHUSZTER, NORBET       On     04/15/2014      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010851 Licensee Name: RONALD J TESTA, JR.
Firm: 001416 Firm Name: TESTA ELECTRIC CO., INC
Firm Phone: 718-331-2747  Firm Address: 1435 65TH STREET, 2ND FL BROOKLYN NY 11219 

Other Licensees and Firms:
License # Licensee Name Firm # Firm Name Type
009514 TESTA, RONALD 001416 TESTA ELECTRIC CO., INC RESPONSIBLE REP

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $68.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: BRADFORD ROAMAN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001  11A    60  20  30  10         
Buildings Total   60  20  30     10           
Total Units : 123 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 04/26/2014 Notice: 1 - FIRST NOTICE 04/04/2014
Power Issued: 04/26/2014 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  GENERAL WIRING THROUGHOUT APARTMENT.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M330576
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/18/2014 04/04/2014 EDB A (50) (7) Y
INSPECTION COMMENTS: NONE
 
(2) 04/15/2014 04/26/2014 NRS C R E (45) (0) Y
INSPECTION COMMENTS: CERT

OBJECTION FOR APPLICATION #: M330576
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 15) FLEXIBLE CORDS USED AS PERMANENT WIRING METHOD
KITCHEN UCL: FLEX CORD USED AS PERMANENT WIRING
RSLV 03/18/2014 03/18/2014 04/15/2014
 
002 (999) OTHER
PANEL MULTIWIRE CKT: NO GROUPED, NO SIMULT TRIP 210.4
RSLV 03/18/2014 03/18/2014 04/15/2014
 
003 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
PANEL K/O MISSING 110.12A
RSLV 03/18/2014 03/18/2014 04/15/2014
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
PANEL AFCI COMBINATION 210.12
RSLV 03/18/2014 03/18/2014 04/15/2014
 
005 ( 58) FIXTURE NOT PROPERLY LOCATED IN CLOTHES CLOSET
CLOSET CLOTHE CLOSET: NOT APPROVED FIXTURE 410.16
RSLV 03/18/2014 03/18/2014 04/15/2014
 
006 (999) OTHER
T-OUT OUTLET BO (S) NOT BONDED 314.4
RSLV 03/18/2014 03/18/2014 04/15/2014
 
007 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
DINING/ LIV RM: NOT APPROVED LIGHT FIXTURE (UL) AM 110.2A
RSLV 03/18/2014 03/18/2014 04/15/2014