BIS Menu  |  Property Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M329595
Premises: 51 EAST 87 STREET MANHATTAN BIN: 1046917     Block: 1499   Lot: 25
   
Application Completed and Certified

Filed: 55 E 87 ST Census Tract:   150.02 Health Area:  3600
9TH FLOOR / APARTMENT A Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10128 Community Board:   108
DOB Cross Street(s):   MADISON AVENUE,    PARK AVENUE
Status:   C - JOB IS SIGNED OFF 11/16/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/16/2012 8:41 AM
Application Entered:   07/16/2012 Job Start Date:   07/16/2012
Last Change:   11/16/2012 Job End Date:   07/20/2012
Appointment Status:   
Last Inspection By:   MCPARTLAND, BRIAN       On     10/24/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010863 Licensee Name: JOHN M DELUCA
Firm: 002448 Firm Name: DELCO ELECTRICAL CORP.
Firm Phone: 212-221-0068  Firm Address: 4233 ARTHUR KILL ROAD, STE 2A STATEN ISLAND NY 10309 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
L - LIGHTING WORK
Total Fee:  $117.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   Yes
Job Number:  120817875
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JAYA & YUSUF NAHMIYAS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  3  45.00
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
009    55  46  33             
Buildings Total   55  46  33                
Total Units : 139 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/17/2012
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  RELOCATED KITCHEN EQUIPMENT, REPLACED CIRCUIT BREAKER PANELS, REPLACED MOST DEVICES WITH NEW.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M329595
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/05/2012 09/17/2012 JCT A (45) (2) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 10/24/2012 11/16/2012 BMP C R (50) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M329595
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
9-A: RECEPTACLES NOT TAMPER PROOF THROUGH-OUT..... - 406.11
RSLV 09/05/2012 09/05/2012 10/24/2012
 
002 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
9-A: A.F.C.I.PROTECTION NOT PROVIDED IN GENERAL LIVING AREAS OTHERTHAL BEDROOMS
RSLV 09/05/2012 09/05/2012 10/24/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Property Permits  |  Electrical Inspection Work Order  |  Back