| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
( 56) |
ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED KITCHEN: NO G.F.I. PROTECTION IN BASEMENT KITCHEN... - 210.5(B2) |
RSLV |
09/12/2012 |
09/12/2012 |
12/05/2012 |
| |
| 002 |
(999) |
OTHER BASEMENT: CORDS NOT PROPERLY TERMINATED TO BOX...... - 400.10 |
RSLV |
09/12/2012 |
09/12/2012 |
12/05/2012 |
| |
| 003 |
( 31) |
MORE THAN ALLOWABLE # OF CONDUCTORS ARE IN OUTLET BOX BASEMENT: J-BOXES IN CEILING HAVE TOO MANY WIRES..... - 314.16 |
RSLV |
09/12/2012 |
09/12/2012 |
12/05/2012 |
| |
| 004 |
( 56) |
ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED BSMT: FLEX CORD USED AS PERMENENT WIRING FOR REFRIDGERATOR(KITCHEN) |
RSLV |
12/05/2012 |
01/25/2013 |
10/03/2013 |
| |
| 005 |
( 56) |
ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED BSMT:EXTENSION CORD TERMINATED IN CEILING |
RSLV |
12/05/2012 |
12/05/2012 |
01/25/2013 |
| |
| 006 |
( 56) |
ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED BSMT: NEED STRAIN RELEASE CORD FOR KITCHEN COUNTER TOP |
RSLV |
12/05/2012 |
12/05/2012 |
01/25/2013 |
| |
| 007 |
(999) |
OTHER BSMT: MULTIWIRE CKT NO GROUPED,NO SIMULTANIOUS TRIP... - 210.4 |
RSLV |
12/05/2012 |
01/25/2013 |
10/03/2013 |
| |
| 008 |
( 25) |
ARMORED CABLES ARE NOT PROPERLY TERMINATED BSMT: MC CABLE NOT PROPERLY TERMINATED IN PANEL..... - 300.40 |
RSLV |
12/05/2012 |
01/25/2013 |
10/03/2013 |
| |
| 009 |
( 34) |
KNOCKOUTS ARE NOT CLOSED IN PANEL BOX BSMT KITCHEN PNL MISSING K/O SEAL ART.110.12A |
RSLV |
01/25/2013 |
01/25/2013 |
10/03/2013 |