BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M327895
Premises: 114 EAST 23 STREET MANHATTAN BIN: 1018032     Block: 878   Lot: 65
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 120 E 23 ST Census Tract:   68 Health Area:  5300
4TH @ 5TH FL. Admin Area:   M - MANHATTAN Inspection Area:   N
NEW YORK, NY 10010 Community Board:   105
DOB Cross Street(s):   PARK AVENUE SOUTH,    LEXINGTON AVENUE
Status:   C - JOB IS SIGNED OFF 09/10/2021
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/02/2012 10:53 AM
Application Entered:   06/02/2012 Job Start Date:   06/04/2012
Last Change:   09/10/2021 Job End Date:   08/30/2012
Appointment Status:   
Last Inspection By:   GANITIS, PHILLIP       On     09/10/2021      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010590 Licensee Name: DEMETRIOS VOUYIOUKLIS
Firm: 000755 Firm Name: JIM ELECTRIC CORP.
Firm Phone: 718-833-2389  Firm Address: 223 52ND STREET BROOKLYN NY 11220 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
T - TEMPORARY LIGHT & POWER
Total Fee:  $160.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: LUIS IGLESIAS
Owner Business Name: COLLIERS INTERNATIONAL
Authorized Representative:  LUIS IGLESIAS
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  2  #8
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  100 AMP 8-16
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
004    60      60             
005    60      60             
Buildings Total 120  12      120                
Total Units : 252 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  G01088C

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M327895
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/10/2021 09/10/2021 PHG C (20) (0) Y
INSPECTION COMMENTS: TEMP REMOVED WE WORK