Electrical Application Details for App #: M325015
Premises: 155 CHAMBERS STREET MANHATTAN BIN: 1001504     Block: 140   Lot: 9
   
Application Completed and Certified

Filed: 155 CHAMBERS ST Census Tract:   21 Health Area:  7700
CEL/1FLR Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10007 Community Board:   101
DOB Cross Street(s):   HUDSON STREET,    GREENWICH STREET
Status:   C - JOB IS SIGNED OFF 11/08/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  03/19/2012 6:15 PM
Application Entered:   03/19/2012 Job Start Date:   03/27/2012
Last Change:   11/08/2012 Job End Date:   06/30/2012
Appointment Status:   
Last Inspection By:   FAY, RICHARD       On     10/17/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012351 Licensee Name: CONROY A SIMPSON
Firm: 004137 Firm Name: ACS ELECTRICAL CORP
Firm Phone: 347-967-5802  Firm Address: 1732 FLATBUSH AVENUE BROOKLYN NY 11210 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $127.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   D2-ELEVATOR APT
Special Cert Approval:   E - EMERGENCY LIGHTING LOCAL LAW 16/84
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JOSEPH CIRIELLO
Owner Business Name: DBTG CHAMBERS LLC
Authorized Representative:  MARK KOISKI
Relationship To Owner:   PARTNER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  #2
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  100AMP SUBPANEL
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
CEL    12               
001    34  18    14             
Buildings Total 46  25    22                
Total Units : 100 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 09/27/2012
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  ALTERATION EXISTING EATER NEW LIGHTING AND POWER .JOB#120986120

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M325015
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/19/2012 09/27/2012 MFF A (30) (3) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 10/17/2012 11/08/2012 RFY C R (45) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M325015
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (286) NO GFCI IN COMMERCIAL KITCHEN
1ST FL: SERVICE AREA COUNTER OUTLETS ARE NOT G.F.C.I.PROTECTED... -ART.210.8(B2)
RSLV 09/19/2012 09/19/2012 10/17/2012
 
002 ( 36) CONDUCTORS ARE NOT PROPERLY COLOR CODED
1ST FL: ELECTRICAL PANEL KITCHEN AREA WHITE WIRE CONNECTED OM THEBREAKER...... - ART.210
RSLV 09/19/2012 09/19/2012 10/17/2012
 
003 ( 36) CONDUCTORS ARE NOT PROPERLY COLOR CODED
1ST FL: ELECTRICAL PANEL KITCHEN AREA ORANGE WIRES ARE IN USE... -ART.210
RSLV 09/19/2012 09/19/2012 10/17/2012



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order