| BUILDING OVERVIEW |
Are Feeders Being Installed? : No |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
0 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
0 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
0 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
0 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
| OBJECTION ID |
OBJECTION CODE |
OBJECTION DESCRIPTION & COMMENTS |
STAT |
FIRST |
LATEST |
RESLVD |
| |
| 001 |
( 16) |
DEFECTIVE LIGHTING FIXTURES ARE IN USE 8A,H: ALL CEILING AND WALL FIXTURE IS OPEN BULB TEMP... - 110.2A |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 002 |
(311) |
FIXTURE NOT APPROVED FOR DAMP/WET LOCATION 8A,H: BATHROOM LIGHT FIXTURE NOT APPROVED...... - 410.10 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 003 |
( 63) |
RECEPTACLE OUTLETS NOT IN SUFFICIENT NUMBER 8A,H: KITCHEN RECEPTACLE NOT IN SUFFICIENT NUMBER..... - 210.52 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 004 |
(311) |
FIXTURE NOT APPROVED FOR DAMP/WET LOCATION 8A,H: BALCONY LIGHT FIXTURE NOT APPROVED...... - 410.10 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 005 |
(999) |
OTHER 8A,H: BALCONY RECEPTACLE NOT WTR..... - 406.8A |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 006 |
( 35) |
APPROVED OUTLETS HAVE NOT BEEN PROVIDED FOR AIR CONDITIONERS 8A,H: OUTLET NOT PROVIDED FOR A/C.... - AM 210.52I |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 007 |
(340) |
RECEPTACLES NOT TAMPERPROOF 8A,H: RECEPTACLE NOT TAMPER PROOF....... - 406.11 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 008 |
( 59) |
AFCI PROTECTION HAS NOT BEEN PROVIDED 8A: A.F.C.I.PROTECTION NOT PROVIDED.... - 210.12 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 009 |
(128) |
NEUTRAL IS GROUNDED BEYOND LOAD SIDE OF SERVICE SWITCH 8A,H: PANEL NEUTRAL BONDED AFTER SERV.SW.... - 250.24A5 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 010 |
(211) |
RECEPTACLE IS NOT PROPERLY BONDED/GROUNDED 8A,H: RECEPTACLE NOT BONDED/GND...... - 250.146 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 011 |
(999) |
OTHER 8A,H: RECEPTACLE NOT FLUSH WITH COMBUSTIBLE..... - 314.20 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 012 |
(132) |
EQUIPMENT/MATERIAL IS NOT PROPERLY GROUNDED 8A,H: LIGHT FIXTURE NOT BOUND/GND..... - 250.4 |
OPEN |
06/13/2013 |
06/13/2013 |
|
| |
| 013 |
( 58) |
FIXTURE NOT PROPERLY LOCATED IN CLOTHES CLOSET 8A,H: LIGHT IN CLOTHES CLOSET NOT APPROVED.... - 410.16 |
OPEN |
06/13/2013 |
06/13/2013 |
|