Electrical Application Details for App #: M319312
Premises: 4 ALBANY STREET MANHATTAN BIN: 1088442     Block: 53   Lot: 7502
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 123 WASHINGTON ST Census Tract:   13 Health Area:  7700
39TH - 59ST STREET Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10006 Community Board:   101
DOB Cross Street(s):   CARLISLE STREET,    ALBANY STREET
Status:   C - JOB IS SIGNED OFF 01/11/2016
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   02/04/2015 Job Start Date:   02/04/2015
Last Change:   01/11/2016 Job End Date:   11/22/2015
Appointment Status:   
Last Inspection By:   CONROY BLAKE       On     12/21/2015      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012151 Licensee Name: ANTHONY DAIDONE
Firm: 003853 Firm Name: E & M ELEC'L CONTR'G COR
Firm Phone: 718-849-0528  Firm Address: 74-10 69 ROAD MIDDLE VILLAGE NY 11379 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $69.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   H - Hotel
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 123 WASHINGTON LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
M39                     
M40                     
M41                       
M42                     
M43                       
M44                       
M45                       
M46                       
M47                       
M48                       
M49                       
M50                       
M51                       
M52                       
M53                       
M54                       
M55                       
M57                       
M58                       
M59                       
Buildings Total   68                      
Total Units : 68 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: C - CALL TO OFFICE 03/31/2015
Power Issued: Response: F - FILED TO REMOVE OBJECTION 02/04/2015

Follow-Up: X - FILED APPL,NOW CLOSED 02/04/2015
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M319312
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/29/2011 10/03/2011 WMK W (30) (6)
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 03/03/2015 03/11/2015 NRS V Y (60) (1) Y
INSPECTION COMMENTS: .CONTRACTOR NEEDS AMEND APP.FLOOR DESCRIPTIONS NOT PROPERLY FILLED IN
 
(3) 03/23/2015 03/31/2015 TOR J X (20) (0) Y
INSPECTION COMMENTS: NEED MORE TIME. THIS IS ONLY APP FOR GENERAL WIRING ALL APTS. NEED'S PROPER FILLING
 
(4) 11/18/2015 11/18/2015 HMC J Y (5) (0) Y
INSPECTION COMMENTS: NONE
 
(5) 11/18/2015 11/18/2015 HMC J Y (5) (1) Y
INSPECTION COMMENTS: NONE
 
(6) 12/21/2015 12/22/2015 CBK C R (60) (0)
INSPECTION COMMENTS: SEE APPLICATION # M375924

OBJECTION FOR APPLICATION #: M319312
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
(ALL FLOORS)FOR REWIRING ALL APTS ON 39TH TO 59TH FL AND APTS 33G,33H
RSLV 09/29/2011 11/18/2015 12/21/2015
 
002 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
(ALL FLOORS)ALL APTS ON 39TH TO 59TH FL.KITCHEN UNDER CABNET LIGHTING ABOVECOUNTER
RSLV 09/29/2011 11/18/2015 12/21/2015
 
003 ( 29) OUTLET BOXES ARE NOT COVERED
THRU-OUT 39TH TO 59TH FL
RSLV 09/29/2011 09/29/2011 03/03/2015
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
APT.33G & 33H - DEFECTIVE CIRCUIT BREAKER
RSLV 09/29/2011 11/18/2015 11/18/2015
 
005 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
APT.33G & 33H - DEFECTIVE CIRCUIT BREAKER
RSLV 09/29/2011 03/23/2015 11/18/2015
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
ALL APTS ON 39TH TO 59TH FL.KITCHEN UNDER CABNETS FIXTURES
RSLV 09/29/2011 03/23/2015 11/18/2015
 
007 (356) RACEWAY LACKS MECHANICAL CONTINUITY
(ALL FLOORS) 42E: KITCH U.C.L. FREE WIRES BEHIND CABINET
RSLV 03/03/2015 11/18/2015 12/21/2015
 
008 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
(ALL FLOORS)ALL APTS ON 39TH TO 59TH FL KITCHEN UNDER CABINETS FIXTURES
RSLV 11/18/2015 11/18/2015 12/21/2015