Electrical Application Details for App #: M318707
Premises: 561 WEST 23 STREET MANHATTAN BIN: 1012341     Block: 695   Lot: 1
   
Application Completed and Certified

Filed: 184 11 AV Census Tract:   99 Health Area:  5500
BASEMENT 2, 3 AND 4 Admin Area:   M - MANHATTAN Inspection Area:   Q
NEW YORK, NY 10011 Community Board:   104
DOB Cross Street(s):   WEST 23 STREET,    WEST 24 STREET
Status:   C - JOB IS SIGNED OFF 04/18/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  09/14/2011 11:32 PM
Application Entered:   09/14/2011 Job Start Date:   09/14/2011
Last Change:   04/18/2012 Job End Date:   09/12/2012
Appointment Status:   
Last Inspection By:   DORSAINVILLE, R       On     03/12/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 012177 Licensee Name: EWAN PALMER
Firm: 003891 Firm Name: PRINCIPAL ELECTRICAL CORP
Firm Phone: 718-405-7609  Firm Address: 3564 BOSTON ROAD BRONX NY 10469 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $394.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: NICK DUKE
Owner Business Name: OWNER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  400 AMP SWITCH
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  3  #4
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  3  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
002        16                 
003        16                 
004        16                 
Buildings Total     48                    
Total Units : 48 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 1 + New Meters 1 - Removed Meters 1 = Total Meters 1

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/14/2011 Notice:  
Power Issued: 09/14/2011 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  SERVICE WORK AND AC OUTLETS MAX

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M318707
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/12/2012 03/22/2012 RID C E (60) (0) Y
INSPECTION COMMENTS: .NONE