BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M317770
Premises: 400 EAST 59 STREET MANHATTAN BIN: 1040640     Block: 1370   Lot: 46
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 1076 FIRST AV Census Tract:   106.01 Health Area:  4900
FIRST FLOOR AND BASEMENT Admin Area:   M - MANHATTAN Inspection Area:   M
NEW YORK, NY 10022 Community Board:   106
DOB Cross Street(s):   EAST 58 STREET,    EAST 59 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/16/2011 1:44 PM
Application Entered:   08/16/2011 Job Start Date:   08/16/2011
Last Change:   08/22/2025 Job End Date:   12/16/2011
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   FAY, RICHARD       On     11/30/2012      
Field Disp:   A - OBJCTN ISSD: JOB COMPLETE
Energize Recommendation:  
Objection Disposition:  

License #: 011964 Licensee Name: GWENDOLYN REEDY
Firm: 003626 Firm Name: NIVEK ELEC'L CONTR'G INC
Firm Phone: 212-423-9970  Firm Address: 301 EAST 119TH STREET NEW YORK NY 10035 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $111.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   Z - Other
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MIRSA VALENTINO
Owner Business Name: VALENTINO'S RESTAURANT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  3 PH 12 CKT 100A MAIN LUG
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                   
001    57  17                 
Buildings Total 66  23                    
Total Units : 96 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: 1 - FIRST NOTICE 12/08/2012
Power Issued: Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M317770
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/26/2012 04/03/2012 DAH N (30) (0) Y
INSPECTION COMMENTS: NONE
 
(2) 11/30/2012 12/08/2012 RFY A (30) (6) Y
INSPECTION COMMENTS: N/A

OBJECTION FOR APPLICATION #: M317770
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 34) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
BASEMENT PANEL; 110.12(A) KNOCKOUTS ARE NOT CLOSED IN PANEL BOX
OPEN 11/30/2012 11/30/2012
 
002 (999) OTHER
BASEMENT PANEL; TWO WISRES UNDER SAME LUG- (TWO WIRES ON SAMEBREAKER 120.14(A))
OPEN 11/30/2012 11/30/2012
 
003 (286) NO GFCI IN COMMERCIAL KITCHEN
KITCHENS; NO GFCI IN COMMERCIAL KITCHEN 210.8 (B2)
OPEN 11/30/2012 11/30/2012
 
004 ( 53) GFCI HAS NOT BEEN PROVIDED
BEHIND BAR; GFCI HAS NOT BEEN PROVIDED 210.8
OPEN 11/30/2012 11/30/2012
 
005 ( 29) OUTLET BOXES ARE NOT COVERED
7 GANY SWITCH; OUTLET BOXES NOT COVERED 314.23
OPEN 11/30/2012 11/30/2012
 
006 ( 11) FEEDER CONDUCTORS ARE NOT OF PROPER SIZE
BASEEMNT PANEL; FEEDER CONDUCTORS NOT PROPER SIZE 215.2 (A) 1
OPEN 11/30/2012 11/30/2012