Electrical Application Details for App #: M316412
Premises: 114 EAST 23 STREET MANHATTAN BIN: 1018032     Block: 878   Lot: 65
   
Application Completed and Certified

Filed: 120 E 23 ST Census Tract:   68 Health Area:  5300
BASEMENT Admin Area:   M - MANHATTAN Inspection Area:   N
NEW YORK, NY 10010 Community Board:   105
Special Place Name:   H.B.O.
DOB Cross Street(s):   PARK AVENUE SOUTH,    LEXINGTON AVENUE
Status:   C - JOB IS SIGNED OFF 04/10/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  07/08/2011 8:28 AM
Application Entered:   07/08/2011 Job Start Date:   07/11/2011
Last Change:   04/10/2012 Job End Date:   10/12/2011
Appointment Status:   
Last Inspection By:   RIVERA, F       On     03/28/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010183 Licensee Name: FRANK LA GREGA
Firm: 000692 Firm Name: INNER CITY ELEC'L CONTR'S
Firm Phone: 718-768-7003  Firm Address: 160 21ST STREET INC BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $2,497.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   REQUIRED
Advisory Board Categories:      K - 1000 KVA SERVICE                            
Advisory Board Approval #:        Submittal #:   
Owner / Occup: FALLS GAVIN
Owner Business Name: AMA CONSULTING
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  4 #-4
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  27  6-600, 8-350,4-600,9-400
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  3  1-1600AMP & 1000 AMP
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    10    10          750 
Buildings Total 10    10               750 
Total Units : 778 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 01/26/2012
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M316412
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/17/2012 01/26/2012 GYM V (190) (5) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 03/28/2012 03/31/2012 FRI C R (90) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M316412
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
BSMT: NEW 1200A DISC SW 1200AMP KRPC,LAYOUT IS NOT AS PER DRAWINGCALENDAR #49480 REV 1 FOR UPS ROOM..... - ART.110.2
RSLV 01/17/2012 01/17/2012 03/28/2012
 
002 (999) OTHER
A) BSMT: 350 MCM CU/PH PN IN 8" X 8" TROUGH LAYOUT IS NOT AS PERDRAWING CALENDAR #49480 REV 1 FOR UPS ROOM.... - ART.110.2
RSLV 01/17/2012 01/17/2012 03/28/2012
 
003 (999) OTHER
B) PROVIDE FUSES CO-ORDINATION 1600AMP KPR - C - 1600A SP IR 300KAWITH 1600AMP CIRCUIT BREAKER
RSLV 01/17/2012 01/17/2012 03/28/2012
 
004 ( 14) CIRCUIT OVERCURRENT PROTECTION DEVICE IS OF IMPROPER SIZE
BSMT: 4 SETS OF 500 KCMIL FEEDER PROTECTED AS 1600AMP(SER SWS #21600AMP UPS ROOM)
RSLV 01/17/2012 01/17/2012 03/28/2012
 
005 (999) OTHER
C) BSMT
RSLV 01/17/2012 01/17/2012 03/28/2012