Electrical Application Details for App #: M316160
Premises: 162 EAST 80 STREET MANHATTAN BIN: 1047485     Block: 1508   Lot: 46
   
Application Completed and Certified

Filed: 162 E 80 ST Census Tract:   140 Health Area:  3600
162 EAST 80TH STREET Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10075 Community Board:   108
DOB Cross Street(s):   LEXINGTON AVENUE,    3 AVENUE
Status:   C - JOB IS SIGNED OFF 05/16/2012
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  06/29/2011 6:41 PM
Application Entered:   06/29/2011 Job Start Date:   07/01/2011
Last Change:   05/16/2012 Job End Date:   07/30/2011
Appointment Status:   
Last Inspection By:   GARY MCCALLA       On     03/14/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 012171 Licensee Name: ROBERT JONES
Firm: 003882 Firm Name: F.I. ELECTRICAL CORP
Firm Phone: 718-986-8454  Firm Address: 34 MALCOLM X BLVD BROOKLYN NY 11221 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $60.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: RICHARD BESSEY
Owner Business Name: RICHARD BESSEY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
005  5C  11    11             
Buildings Total 11    11                
Total Units : 33 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 02/02/2012
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  TO ADD A NEW GFI OUTLET,RUN TWO DEDICATED LINES ONE FOR ANDAND THE FOR A MICROWAVE AND REPLACE TRACK LIGHTING WITH PENDANT MOUNTED LAMP

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M316160
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/26/2012 02/02/2012 DAH A (45) (8) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 03/14/2012 03/26/2012 GYM C R (65) (0) Y
INSPECTION COMMENTS: APT 5C 1 NEW PANEL

OBJECTION FOR APPLICATION #: M316160
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 (999) OTHER
PNL: NEUT BONDED AFTER SVC (IN PNL)..... - 250
RSLV 01/26/2012 01/26/2012 03/14/2012
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
KITCHEN: TWO CHANDELLIERS
RSLV 01/26/2012 01/26/2012 03/14/2012
 
003 ( 19) DEFECTIVE WIRING IS IN USE
A) PNL: LOCK NUT MISSING AT FDR (3/4" CONNECTOR)
RSLV 01/26/2012 01/26/2012 03/14/2012
 
004 ( 19) DEFECTIVE WIRING IS IN USE
B) PNL: MULTI CONDUCTOR AT 20A CKT BKR(3 OF THEM #4,7 & 8 RESPECTIVELY)
RSLV 01/26/2012 01/26/2012 03/14/2012
 
005 ( 56) ELECTRICAL MATERIAL USED IS NOT SUITABLE FOR THE PURPOSE INTENDED
KITCHEN: SHEET ROCK SCREWS IN USE OR DEVICES
RSLV 01/26/2012 01/26/2012 03/14/2012
 
006 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
A) G.F.C.I.NOT PROPERLY GROUPEED
RSLV 01/26/2012 01/26/2012 03/14/2012
 
007 ( 19) DEFECTIVE WIRING IS IN USE
C) TWELVE (2) BRANCH CKT OR QUAD #1 & 220V
RSLV 01/26/2012 01/26/2012 03/14/2012
 
008 ( 46) PANEL HAS NOT BEEN PROVIDED WITH A DIRECTORY
PNL: DIRECTORY NOT PROVIDED*NOT A FINAL*
RSLV 01/26/2012 01/26/2012 03/14/2012