Electrical Application Details for App #: M305606
Premises: 25 WAVERLY PLACE MANHATTAN BIN: 1008835     Block: 548   Lot: 21
   
Application Completed and Certified

Filed: 25 WAVERLY PL Census Tract:   5900 Health Area:  5700
BASEMENT MOTOR ROOM Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10003 Community Board:   102
DOB Cross Street(s):   GREENE STREET,    UNIVERSITY PLACE
Status:   C - JOB IS SIGNED OFF 01/04/2011
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/11/2010 10:14 AM
Application Entered:   08/11/2010 Job Start Date:   08/13/2010
Last Change:   01/04/2011 Job End Date:   09/13/2010
Appointment Status:   
Last Inspection By:   DALTON HENLON       On     10/12/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009849 Licensee Name: CHAIM WRUBEL
Firm: 000678 Firm Name: HY-LEE ELECTRIC CO., INC.
Firm Phone: 718-886-1913  Firm Address: 14-34 110TH STREET SUITE 102 COLLEGE POINT NY 11356 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $63.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: NYU
Authorized Representative:  JAMIE WEKERLE
Relationship To Owner:   ELEVATOR CONTRACTOR


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  100-AMPERE
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  6-CIRCUIT PANELETTE
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS                   
Buildings Total                   
Total Units : 4 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REMOVE AND REPLACE MAIN LIGHT SWITCH AND CIRCUIT BREAKER BOX IN MOTOR ROOM.

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M305606
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 10/12/2010 10/20/2010 DAH C (45) (0) Y
INSPECTION COMMENTS: NONE