Electrical Application Details for App #: M295237
Premises: 106 HUDSON STREET MANHATTAN BIN: 1066469     Block: 189   Lot: 7502
   
Application Completed and Certified

Filed: 110 HUDSON ST Census Tract:   33 Health Area:  7700
8, 9 & 10 FLOOR Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10013 Community Board:   101
DOB Cross Street(s):   FRANKLIN STREET,    NORTH MOORE STREET
Status:   C - JOB IS SIGNED OFF 02/17/2010
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/12/2009 9:43 PM
Application Entered:   08/12/2009 Job Start Date:   08/12/2009
Last Change:   02/17/2010 Job End Date:   06/15/2010
Appointment Status:   
Last Inspection By:   CHARLES COURTNEY       On     02/09/2010      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 009295 Licensee Name: LAZAR MOSES
Firm: 003491 Firm Name: NORI ELECTRIC, INC
Firm Phone: 212-868-1090  Firm Address: 436 WEST 18TH ST, 2NF FL REAR NEW YORK NY 10001 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
7 - HVAC WIRING
Total Fee:  $733.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: MICHAEL NOVOGRATZ
Owner Business Name: RESIDENCE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  SET OF 4 #2AWG
B. Over #2 to 1/0  3  2 SETS OF 4 #1/0 / 4 #1
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  7  200A, 3PH, 4W, 42P
D. 3 Phase Over 225 AMPS  1  300A, 3PH, 4W, 42P
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
008    46  42    10  46         
009    98  54    98         
010    68  41    68             
PEN    12  18    12             
ROF        14         
Buildings Total 228  155    23  228     29           
Total Units : 663 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 11/12/2009
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M295237
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/05/2009 11/12/2009 CCH A (90) (4) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 02/09/2010 02/17/2010 CCH C R (45) (0) Y
INSPECTION COMMENTS: BEDROOM FIXTURE REMOVED

OBJECTION FOR APPLICATION #: M295237
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 37) MOTOR DISCONNECT SWITCH HAS NOT BEEN PROVIDED
KITCHEN: NO DIS SW FOR WALK-IN FRIDGE
RSLV 11/05/2009 11/05/2009 02/09/2010
 
002 ( 22) FIXED EQUIPMENT IS NOT PROPERLY GROUNDED
BEDROOM: NO GROUNDING HANGING FIXTURE
RSLV 11/05/2009 11/05/2009 02/09/2010
 
003 ( 28) ELECTRICAL MATERIAL USED FOR LUMINAIRES HAS NOT BEEN APPROVED
BEDROOM: FIXTURE NOT APPROVED
RSLV 11/05/2009 11/05/2009 02/09/2010
 
004 (999) OTHER
KITCHEN: ISLAND OUTLET NOT ACCESSIBLE OVER 12"350.52.C.2
RSLV 11/05/2009 11/05/2009 02/09/2010