Electrical Application Details for App #: M283562
Premises: 29 WEST 12 STREET MANHATTAN BIN: 1009626     Block: 576   Lot: 55
   
Application Completed and Certified

Filed: 29 W 12 ST Census Tract:   63 Health Area:  5700
BASEMENT, 4FL,16 APTS Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10011 Community Board:   102
DOB Cross Street(s):    5 AVENUE,    AVENUE OF THE AMERICAS
Status:   C - JOB IS SIGNED OFF 05/15/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  08/04/2008 12:37 PM
Application Entered:   08/04/2008 Job Start Date:   08/04/2008
Last Change:   05/15/2009 Job End Date:   12/31/2008
Appointment Status:   
Last Inspection By:   HINDS EUGENE       On     04/22/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010910 Licensee Name: DAVID HARARI
Firm: 002193 Firm Name: VEGA ELECTRIC CORP.
Firm Phone: 347-386-1908  Firm Address: 2886 NOSTRAND AVENUE BROOKLYN NY 11229 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $677.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: JO ECKSTEIN
Owner Business Name: 29 WEST 12 LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  1  600AMPS
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  2SETSOF 500 MCM
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  16  100A
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 64  192  16  64  64                
Total Units : 400 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 16 #4-Wire 0 #10-Wire 1
Existing Meters 1 + New Meters 17 - Removed Meters 1 = Total Meters 17

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 08/04/2008 Notice: 1 - FIRST NOTICE 04/08/2009
Power Issued: 08/04/2008 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  REWIRE 16 APTS,16 NEW METERS+1PLP 3PHASE 400 AMPS

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M283562
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/31/2009 04/08/2009 CCH A E (45) (5) Y
INSPECTION COMMENTS: NO ACCESS TO ALL APARTMENTS - FEEDERS TO APARTMENTS TO BE CHECKED SEE VIOLATION DETAILS
 
(2) 04/22/2009 04/30/2009 EHD C R E (30) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M283562
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 7) EMT IS NOT PROPERLY SUPPORTED (TYPE:EMT)
BASEMENT: E.M.T.NOT SUPPORTED (WATER GROUND)
RSLV 03/31/2009 03/31/2009 04/22/2009
 
002 ( 10) BRANCH CIRCUIT CONDUCTORS ARE NOT PROPER SIZE
BASEMENT: 70 AMPS BREAKER ON #10 WIRE
RSLV 03/31/2009 03/31/2009 04/22/2009
 
003 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
BASEMENT: SER ENTRANCE RACEWAY NOT PROPERLY BONDED
RSLV 03/31/2009 03/31/2009 04/22/2009
 
004 ( 59) AFCI PROTECTION HAS NOT BEEN PROVIDED
5A: ALL A/C ON ONE ARC FAULT BREAKER
RSLV 03/31/2009 03/31/2009 04/22/2009
 
005 (999) OTHER
3A: NEED CT OUTLET LEFT SIDE SINK.....210.52B*NOT FINAL*
RSLV 03/31/2009 03/31/2009 04/22/2009