Electrical Application Details for App #: M281494
Premises: 244 WEST 26 STREET MANHATTAN BIN: 1014206     Block: 775   Lot: 64
   
Application Completed and Certified

Filed: 250 W 26 ST Census Tract:   91 Health Area:  5200
BSMT-ELECTRICAL ROOM Admin Area:   M - MANHATTAN Inspection Area:   P
NEW YORK, NY 10001 Community Board:   104
DOB Cross Street(s):    7 AVENUE,    8 AVENUE
Status:   C - JOB IS SIGNED OFF 11/10/2009
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   09/04/2008 Job Start Date:   09/10/2008
Last Change:   11/10/2009 Job End Date:   11/15/2008
Appointment Status:   
Last Inspection By:   HINDS EUGENE       On     10/22/2009      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011199 Licensee Name: NICHOLAS V BALZANO
Firm: 002604 Firm Name: BALZANO ELECTRIC CORP.
Firm Phone: 718-788-1448  Firm Address: 4706 NEW UTRECHT AVENUE BROOKLYN NY 11219 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
9 - OTHER
Total Fee:  $715.00
Other Work:   REMOVAL OF VIOLATION
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   I - Hospital Or Health Facility
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: HAG REALEY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  1  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  4  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 03/16/2009
Power Issued: Response: F - FILED TO REMOVE OBJECTION 09/04/2008

Follow-Up: X - FILED APPL,NOW CLOSED 09/04/2008
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M281494
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/03/2008 06/07/2008 RID W (15) (6)
INSPECTION COMMENTS: NONE
 
(2) 03/05/2009 03/16/2009 CLC A R (30) (4) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(3) 10/22/2009 10/28/2009 EHD C R (30) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M281494
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 4) SERVICE IN EXCESS OF 1000KVA HAS NOT BEEN SUBMITTED FOR APPROVAL
MORE THAN 6 SER IN THE BUILDING
RSLV 06/03/2008 06/03/2008 03/05/2009
 
002 ( 29) OUTLET BOXES ARE NOT COVERED
OPEN 119 BOXES THRU OUT BSMT
RSLV 06/03/2008 06/03/2008 03/05/2009
 
003 ( 25) ARMORED CABLES ARE NOT PROPERLY TERMINATED
THRU OUT BSMT
RSLV 06/03/2008 06/03/2008 03/05/2009
 
004 ( 26) ARMORED CABLES ARE INSTALLED EXPOSED
THRU OUT BSMT
RSLV 06/03/2008 06/03/2008 03/05/2009
 
005 ( 27) ARMORED CABLES INSTALLED WITHOUT INSULATING BUSHINGS
THRU OUT BSMT
RSLV 06/03/2008 06/03/2008 03/05/2009
 
006 ( 19) DEFECTIVE WIRING IS IN USE
THRU OUT THE BSMT, NOT A FINAL INSPECTION SEE M270502
RSLV 06/03/2008 06/03/2008 03/05/2009
 
007 (999) OTHER
BSMT: SERVICE END COND RAN IN PARALELL NOT THE SAME310.4
RSLV 03/05/2009 03/05/2009 10/22/2009
 
008 (999) OTHER
BSMT: SERVICE COPPER DETAIL BOX LINE AND LOAD SAME RACEWAY230.7
RSLV 03/05/2009 03/05/2009 10/22/2009
 
009 (999) OTHER
BSMT: SUPPLEMENTAL AND RACEWAY NOT CONTINUOUS250
RSLV 03/05/2009 03/05/2009 10/22/2009
 
010 (999) OTHER
BSMT: SERVICE SW FUSES OVER 601 AMP NOT CO-ORDINATE EITH 2ND FUSE240.12
RSLV 03/05/2009 03/05/2009 10/22/2009