BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M277260
Premises: 374 BROADWAY MANHATTAN BIN: 1001866     Block: 172   Lot: 7501
   
Application Completed and Certified

Filed: 376 BROADWAY Census Tract:   31 Health Area:  7700
FRONT STORE AND BASEMENT Admin Area:   M - MANHATTAN Inspection Area:   W
NEW YORK, NY 10013 Community Board:   101
DOB Cross Street(s):   FRANKLIN STREET,    WHITE STREET
Status:   C - JOB IS SIGNED OFF 02/06/2009
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  02/15/2008 11:08 AM
Application Entered:   02/15/2008 Job Start Date:   02/15/2008
Last Change:   02/06/2009 Job End Date:   05/15/2008
Appointment Status:   
Last Inspection By:   RIVERA, F       On     08/14/2008      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011749 Licensee Name: JEROME DALY
Firm: 003344 Firm Name: AMRA ELECTRICAL CORP
Firm Phone: 718-444-5209  Firm Address: 1415 UTICA AVENUE BROOKLYN NY 11201 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $448.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   DAVID Z
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: NYZ OUTLET LLC
Authorized Representative:  HILLA LEVY
Relationship To Owner:   MANAGER


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   Yes
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  4  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  4  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 30  15    10  30     40           
Total Units : 125 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice: 1 - FIRST NOTICE 06/19/2008
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M277260
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/12/2008 06/19/2008 HRB V (60) (4) Y
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 08/14/2008 08/19/2008 FRI C R (30) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M277260
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 1) SERVICE EQUIPMENT ENCLOSURES ARE NOT BONDED TOGETHER
BASEMENT: NEW SWITCH IN SERVICE ROOM IN BASEMENT
RSLV 06/12/2008 06/12/2008 08/14/2008
 
002 ( 29) OUTLET BOXES ARE NOT COVERED
1ST FLR/BASEMENT: THROUGH-OUT 1ST FLR AND BASEMENT OF SPACE
RSLV 06/12/2008 06/12/2008 08/14/2008
 
003 ( 33) KNOCKOUTS ARE NOT CLOSED IN OUTLET BOX
1ST FLR/BASEMENT: THROUGH-OUT 1ST FLR AND BASEMENT
RSLV 06/12/2008 06/12/2008 08/14/2008
 
004 ( 45) FIXTURE NOT INSTALLED IN AN APPROVED MANNER
1ST FLR: EXIT SIGNS ARE NOT SUPPORTED PROPERLY
RSLV 06/12/2008 06/12/2008 08/14/2008



If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back