Electrical Application Details for App #: M263908
Premises: 227 SULLIVAN STREET MANHATTAN BIN: 1008667     Block: 539   Lot: 10
   
Application Completed and Certified

Filed: 227 SULLIVAN ST Census Tract:   65 Health Area:  5700
HALLWAYS\STAIRWAY Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   BLEECKER STREET,    WEST 3 STREET
Status:   C - JOB IS SIGNED OFF 06/05/2012
Request Type:   P - PICK-UP eFiled:   YES
Application Entered:   01/19/2012 Job Start Date:   01/19/2012
Last Change:   06/05/2012 Job End Date:   01/24/2012
Appointment Status:   
Last Inspection By:   CHARLES COURTNEY       On     05/21/2012      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010185 Licensee Name: SALVATORE TRINCERI
Firm: 001444 Firm Name: TRINCE ELECTRIC INC.
Firm Phone: 212-481-1261  Firm Address: 28 PERRY STREET NEW YORK NY 10014 

Work Started or Filed by Others: YES
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $48.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: 227 SULLIVAN ST ASSOC
Authorized Representative:  CAROLINE PALMIERI
Relationship To Owner:   MGT AGENT


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
001                   
002                   
003                   
004                   
005                   
Buildings Total                   
Total Units : 27 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  03/01/2007
Power Issued: Response: F - FILED TO REMOVE OBJECTION 01/19/2012

Follow-Up: X - FILED APPL,NOW CLOSED 01/19/2012
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M263908
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/24/2007 03/01/2007 EBA W (15) (1)
INSPECTION COMMENTS: SEE VIOLATION DETAILS
 
(2) 05/21/2012 06/05/2012 CCH C R (30) (0) Y
INSPECTION COMMENTS: NONE

OBJECTION FOR APPLICATION #: M263908
OBJECTION ID OBJECTION CODE OBJECTION DESCRIPTION & COMMENTS STAT FIRST LATEST RESLVD
 
001 ( 3) APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION NOT ON FILE
NO APLICATION ON FILE FOR FIXTURES,EXIT SIGNS,BRANCH CIRCUITS INHALLWAYS AND STAIRS
RSLV 02/24/2007 02/24/2007 05/21/2012