BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M210998
Premises: 605 PARK AVENUE MANHATTAN BIN: 1042391     Block: 1399   Lot: 74
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 605 PARK AV Census Tract:   120 Health Area:  4100
053399 16 A Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10021 Community Board:   108
DOB Cross Street(s):   EAST 64 STREET,    EAST 65 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   C - COMPLAINT eFiled:   NO
Application Entered:   04/16/2002 Job Start Date:   06/18/2002
Last Change:   08/22/2025 Job End Date:   09/18/2002
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   RIVERA, F       On     12/11/2007      
Field Disp:   J - JOB IN PROGRESS
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 011197 Licensee Name: PHAT QUACH
Firm: 002600 Firm Name: MODERN TREND ELECL CONTRG
Firm Phone: 718-699-3300  Firm Address: 45-06 108TH STREET-2ND FL. CORP. CORONA NY 11368 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $72.00
Other Work:   REMOVAL OF VIOLATION
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   X
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: RUBLER NEIL
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   37  21  14                
Total Units : 74 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  05/22/2002
Power Issued: Response: F - FILED TO REMOVE OBJECTION 06/25/2002

Follow-Up: F - FILED TO REMOVE OBJECTION 06/25/2002
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M210998
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/25/2002 05/06/2002 SR2 N (15) (0)
INSPECTION COMMENTS: N/A
 
(2) 05/15/2002 05/22/2002 SR2 W (90) (3) Y
INSPECTION COMMENTS: 1WIRING REMOVAL2WIRING THRU OUT APT#8A3(100A)+NEW BRANCH CIRCUIT UNI TS+WIRING BEING INSTALLED THRU OUT APT
 
(3) 09/04/2003 09/10/2003 PAT N (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/11/2007 12/18/2007 FRI J R (1) (0) Y
INSPECTION COMMENTS: REDIRECT VIOLATION TO OWNER




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.