Electrical Application Details for App #: M197291
Premises: 400 EAST 74 STREET MANHATTAN BIN: 1045887     Block: 1468   Lot: 45
   
Application Completed and Certified

Filed: 400 E 74 ST Census Tract:   124 Health Area:  4300
180310 BSMT ELECT.RM Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10021 Community Board:   108
DOB Cross Street(s):    1 AVENUE,    YORK AVENUE
Status:   C - JOB IS SIGNED OFF 06/19/2001
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/23/2001 Job Start Date:   01/17/2001
Last Change:   06/19/2001 Job End Date:   01/31/2001
Appointment Status:   
Last Inspection By:   REDDINGTON, J.       On     06/15/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010799 Licensee Name: JOSEPH MARCHESE
Firm: 002033 Firm Name: CROSSLAND ELECT'L SYS INC
Firm Phone: 718-629-0260  Firm Address: 846 EAST 52ND STREET BROOKLYN NY 11203 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $143.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   TELECOMMUNICATION
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: VOICE STREAM WIRELESS
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                        90 
Total Units : 90 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/23/2001 Notice:  
Power Issued: 01/23/2001 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: (CELL SITE) (EXISTING SER UPGRADED FROM 100AMP TO 200AMP)
Contractor's Comments:  ROOF(THIS IS AN EXISING SERVICE BEING UPGRADED)(CELL SITE)

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M197291
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/23/2001 04/25/2001 PC2 N (30) (0)
INSPECTION COMMENTS: APT BLDG FRT DOOR LOCKED SUPT NOT ANSWER LEFT CARD IN DOOR
 
(2) 06/15/2001 06/19/2001 SR2 C E (20) (0) Y
INSPECTION COMMENTS: APT BUILDING FRONT DOOR LOCKED SUPT NO SUCH LEROCALD TO DOOR ARRIVED