Electrical Application Details for App #: M171700
Premises: 161 ALLEN STREET MANHATTAN BIN: 1005512     Block: 416   Lot: 25
   
Application Completed and Certified

Filed: 161 ALLEN ST Census Tract:   36.01 Health Area:  6500
NONE Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10002 Community Board:   103
DOB Cross Street(s):   RIVINGTON STREET,    STANTON STREET
Status:   C - JOB IS SIGNED OFF 10/18/2000
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/26/1998 Job Start Date:   09/21/1998
Last Change:   09/07/2000 Job End Date:   02/28/1999
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     09/05/2000      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009593 Licensee Name: ROBERT GARCIA
Firm: 001256 Firm Name: ROBERT GARCIA ELECL CONT
Firm Phone: 718-993-6737  Firm Address: 500 TRINITY AVENUE, STE.1B CORP BRONX NY 10455 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
2 - TEMPORARY CONSTRUCTION
6 - GENERAL WIRING
Total Fee:  $929.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:   B - BOILER CONTROLS J-51 CERTIFICATION
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: ASIAN AMER. FOR EQUALITY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  2  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  2  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  15  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  14  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 65  325  39  93  75     21           
Total Units : 618 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   NO ACCESS- CALL OFFICE FOR APPOINTMENT Contact Phone:   718-294-1880

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 16 #4-Wire 2 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/07/2000 Notice:  
Power Issued: 09/07/2000 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  NEAR RIVINGTON ST

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M171700
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 04/20/1999 04/21/1999 PGR J (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/05/1999 10/08/1999 SVJ J G (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 09/05/2000 09/07/2000 SVJ C E (75) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application