BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M169489
Premises: 368 10 AVENUE MANHATTAN BIN: 1087875     Block: 729   Lot: 1
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 396 10 AV Census Tract:   103 Health Area:  5500
1ST FL Admin Area:   M - MANHATTAN Inspection Area:   Q
NEW YORK, NY 10001 Community Board:   104
DOB Cross Street(s):   WEST 31 STREET,    WEST 33 STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   08/10/1998 Job Start Date:   03/03/1997
Last Change:   08/22/2025 Job End Date:   03/10/1997
               COMPLETION FEE WAS BILLED
Appointment Status:   
Last Inspection By:   WEISBART, F.       On     09/27/2000      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  
Objection Disposition:  X - NOT REMOVED

License #: 009512 Licensee Name: CHESTER STRUGATS
Firm: 000282 Firm Name: C.M.S. ELEC'L MAINT CO.,I
Firm Phone: 212-765-6130  Firm Address: 135 WEST 50TH STREET NEW YORK NY 10020 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
7 - HVAC WIRING
Total Fee:  $78.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: JOHN HANCOCK MUTUAL LIFE
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  2  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 3 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice: C - CALL TO OFFICE 10/02/2000
Power Issued: Response: F - FILED TO REMOVE OBJECTION 09/01/1998

Follow-Up: F - FILED TO REMOVE OBJECTION 09/01/1998
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M169489
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 08/06/1998 08/10/1998 FWE W (15) (3)
INSPECTION COMMENTS: *A/C UNITS *ROOM RE:M161682
 
(2) 10/27/1998 10/28/1998 FWE H X (40) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/21/1999 01/26/1999 FWE H X (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 09/27/2000 10/02/2000 FWE H X (50) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order