Electrical Application Details for App #: M160446
Premises: 158 ORCHARD STREET MANHATTAN BIN: 1077187     Block: 411   Lot: 7
   
Application Completed and Certified

Filed: 158 ORCHARD ST Census Tract:   30.01 Health Area:  6600
BLDG Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10002 Community Board:   103
DOB Cross Street(s):   RIVINGTON STREET,    STANTON STREET
Status:   C - JOB IS SIGNED OFF 09/02/1998
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   11/13/1997 Job Start Date:   11/11/1997
Last Change:   08/31/1998 Job End Date:   02/11/1998
Appointment Status:   
Last Inspection By:   PETER GREENE       On     08/28/1998      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 009946 Licensee Name: RAFAEL O SEPULVEDA
Firm: 001987 Firm Name: OM ELECTRIC, INC
Firm Phone: 212-944-7799  Firm Address: 262 WEST 38TH STREET, RM 1202 NEW YORK NY 10018 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $890.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 158 ORCHARD ST REALTY LLC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  21  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  23  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 100  175  30  90  100                
Total Units : 495 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   9-5 PM Contact Phone:   212-369-4500

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 21 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 11/13/1997 Notice:  
Power Issued: 11/13/1997 Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M160446
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/22/1998 01/26/1998 PGR J G (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/20/1998 07/21/1998 PGR N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 08/28/1998 08/31/1998 PGR C E (30) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application