BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M139127
Premises: 135 SULLIVAN STREET MANHATTAN BIN: 1008039     Block: 517   Lot: 1
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 135 SULLIVAN ST Census Tract:   49 Health Area:  6800
NONE Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   PRINCE STREET,    WEST HOUSTON STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/03/1996 Job Start Date:   12/26/1995
Last Change:   08/22/2025 Job End Date:   01/31/1996
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     10/05/2001      
Field Disp:   N - NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 010818 Licensee Name: JETHRO J ANTOINE
Firm: 002088 Firm Name: JETHRO J. ANTOINE INC.
Firm Phone: 718-257-3899  Firm Address: 856 CRESCENT STREET BROOKLYN NY 11208 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $394.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 135 SULLIVAN REALTY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  7  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  7  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 28  56  14  28  28                
Total Units : 154 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   8-4:30PM MON-FRI Contact Phone:   212-751-7511

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 27 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 01/03/1996 Notice:  
Power Issued: 01/03/1996 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M139127
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/13/1996 06/18/1996 FWE P (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 07/17/1997 07/28/1997 FWE P (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/29/1999 04/01/1999 SVJ N (10) (0)
INSPECTION COMMENTS: N/A
 
(4) 06/03/1999 06/04/1999 SR2 N (10) (0)
INSPECTION COMMENTS: N/A ABOVE STORE "ONCE UPON A JANT"; NO SUPT
 
(5) 10/01/1999 10/04/1999 SR2 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 10/05/2001 10/10/2001 SVJ N (15) (0)
INSPECTION COMMENTS: LEFT CARD