Electrical Application Details for App #: M138577
Premises: 200 ELDRIDGE STREET MANHATTAN BIN: 1077638     Block: 416   Lot: 1
   

Filed: 200 ELDRIDGE ST Census Tract:   36.01 Health Area:  6500
SP9400016 BLDG#3A Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10002 Community Board:   103
DOB Cross Street(s):   RIVINGTON STREET,    STANTON STREET
Status:   K - CLOSED/CANCELLED 06/24/1996
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   12/12/1995 Job Start Date:   11/06/1995
Last Change:   06/24/1996 Job End Date:   05/30/1996
Appointment Status:   
Last Inspection By:   BUNK, JACK       On     06/20/1996      
Field Disp:   K - OK TO CANCEL
Energize Recommendation:  
Objection Disposition:  

License #: 011137 Licensee Name: STEVE KALLAN
Firm: 002507 Firm Name: KISS ELECTRIC
Firm Phone: 212-987-2525  Firm Address: 60 EAST 54TH STREET NEW YORK NY 10022 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $10.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   L - Five Or More Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: NYCHA
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   SEE BLDG MGR 8-4PM Contact Phone:   212 982-0990

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: INSTALL TELE ENTRY INTERCOM SYSTEM & ELECTRO-MAGNETIC LOCK SYSTEM
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M138577
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 01/26/1996 02/16/1996 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 03/06/1996 03/12/1996 KIW I (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 06/20/1996 06/24/1996 LJB K (2) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application