| BUILDING OVERVIEW |
Are Feeders Being Installed? : |
| (If feeders are being installed, provide a wiring diagram and calculations at the time of inspection) |
| Building Overview Work Items |
QUANTITY |
DESCRIPTION |
| SERVICE SWITCHES |
|
| A. Up to 100 AMPS |
0 |
|
| B. 101 Up to 200 AMPS |
1 |
|
| C. 201 Up to 600 AMPS |
0 |
|
| D. 601 Up to 1200 AMPS |
0 |
|
| E. Over 1200 AMPS |
0 |
|
| SER. ENT. & FDR COND (EACH SET) |
|
| A. Up to #2 CONDUCTOR |
0 |
|
| B. Over #2 to 1/0 |
0 |
|
| C. Over 1/0 to 250 MCM |
1 |
|
| D. Over 250 MCM |
0 |
|
| PANELS |
|
| A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs |
8 |
|
| B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs |
0 |
|
| C. 3 Phase Up to 225 AMPS |
1 |
|
| D. 3 Phase Over 225 AMPS |
0 |
|
| ELEVATORS / ESCALATORS / MATERIAL LIFTS |
|
| A. Total No. of Elevators / Escalators / Material Lifts |
0 |
|
| B. Each Additional 10 Floors Or Less |
0 |
|
| BOILER CONTROLS |
0 |
|
INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
| |
| (1) |
02/24/1997 |
02/27/1997 |
KIW |
V |
|
G |
(45) |
|
(2) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (2) |
03/10/1997 |
03/12/1997 |
KIW |
V |
R |
G |
(45) |
|
(1) |
|
| INSPECTION COMMENTS:
|
/
|
| |
| (3) |
03/27/1997 |
03/31/1997 |
KIW |
H |
X |
|
(45) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (4) |
04/23/1997 |
05/07/1997 |
KIW |
V |
R |
G |
(55) |
|
(1) |
|
| INSPECTION COMMENTS:
|
NEUTRAL ARE NOT BONDED
|
| |
| (5) |
08/05/1997 |
08/15/1997 |
SR2 |
H |
X |
|
(15) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (6) |
08/26/1997 |
08/28/1997 |
SR2 |
N |
|
|
(15) |
|
(0) |
|
| INSPECTION COMMENTS:
|
NO ACCESS THRU REST HAVE CONT ARRANGE APPT
|
| |
| (7) |
02/26/1998 |
03/04/1998 |
SR2 |
N |
|
|
(20) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (8) |
06/15/1998 |
06/19/1998 |
PGR |
V |
R |
G |
(40) |
|
(1) |
|
| INSPECTION COMMENTS:
|
*GROUND 3110.D
|
| |
| (9) |
11/09/1998 |
11/17/1998 |
SVJ |
V |
R |
E |
(85) |
|
(5) |
|
| INSPECTION COMMENTS:
|
APT-LOAD CALCULATION NOT PROVIDED*100A SER SW FOR 8 APT AT 40A *BREAKER PANEL*BREAKER PANEL*PANEL*PANEL-REST-OVER 42 CKT IN C.B.P
|
| |
| (10) |
12/18/1998 |
12/24/1998 |
SVJ |
H |
X |
|
(15) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|
| |
| (11) |
01/05/1999 |
01/08/1999 |
SVJ |
C |
R |
|
(20) |
|
(0) |
|
| INSPECTION COMMENTS:
|
No Inspection Comments For This Application
|