Premises: 1173 LEXINGTON AVENUE MANHATTAN BIN: 1047510     Block: 1509   Lot: 20
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 151 E 80 ST Census Tract:   140 Health Area:  3600
7D Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10021 Community Board:   108
DOB Cross Street(s):   LEXINGTON AVENUE,    3 AVENUE
Status:   E - ABANDONED 08/22/2025
Request Type:   C - COMPLAINT eFiled:   NO
Application Entered:   06/20/1995 Job Start Date:   09/27/1995
Last Change:   08/22/2025 Job End Date:   09/27/1995
Appointment Status:   
Last Inspection By:   REDDINGTON, J.       On     09/24/2001      
Field Disp:   P - PARTIAL NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 010764 Licensee Name: CARMINE GRACI
Firm: 002000 Firm Name: C & A ELECT'L CONTRG CORP
Firm Phone: 718-891-2275  Firm Address: 4706 NEW UTRECHT AV BROOKLYN NY 11219 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $91.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   VARIOUS
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: COOPERATIVE DEVELOPMENT C
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 19                
Total Units : 44 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   ANYTIME Contact Phone:   235-3200

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice:  09/06/1995
Power Issued: Response: F - FILED TO REMOVE OBJECTION 09/27/1995

Follow-Up: F - FILED TO REMOVE OBJECTION 09/27/1995
Wires Comments: 110 VOLT METER TO BE UPGRADED TO 208 V RELOCATED TO BASEMENT
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M132862
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/26/1995 07/31/1995 GO1 W (15) (1)
INSPECTION COMMENTS: FOR SUBFEEDER PANEL & BRANCH CIRCUIT WIRING OF APT 7D
 
(2) 02/04/1997 02/05/1997 SR2 P (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 05/02/1997 11/20/1997 X01 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 10/07/1999 10/12/1999 LEN N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 07/28/2000 08/01/2000 LEN N (10) (0)
INSPECTION COMMENTS: ALSO M133477
 
(6) 09/24/2001 09/26/2001 SR2 P (25) (0)
INSPECTION COMMENTS: PNIA # 7D LEFT CARD