BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M126973
Premises: 160 7 AVENUE SOUTH MANHATTAN BIN: 1067542     Block: 612   Lot: 7501
   
Application Completed and Certified

Filed: 160 7 AV S Census Tract:   73 Health Area:  6400
BSMT Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   CHARLES STREET,    WAVERLY PLACE
Status:   C - JOB IS SIGNED OFF 05/01/2001
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/04/1995 Job Start Date:   12/15/1994
Last Change:   04/17/2001 Job End Date:   03/15/1995
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     04/16/2001      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009802 Licensee Name: PETER J CATANZARO
Firm: 001146 Firm Name: PETER J. CATANZARO, INC.
Firm Phone: 718-832-3230  Firm Address: 126 41ST STREET BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $163.50
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   DOCTORS OFFICE
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: EDWARDS MEDICAL FACILITY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 95  94    28  95     12           
Total Units : 324 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M126973
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/12/1997 06/18/1997 FWE N (10) (0)
INSPECTION COMMENTS: NO ACCESS - GATE ROLLED DOWN
 
(2) 11/05/1998 11/17/1998 SVJ N (10) (0)
INSPECTION COMMENTS: DOORS WERE LOCKED. LEFT CARD
 
(3) 06/08/1999 06/14/1999 SVJ N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 09/23/1999 09/27/1999 SVJ N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 02/15/2000 02/17/2000 SVJ N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 04/16/2001 04/17/2001 SVJ C (30) (0)
INSPECTION COMMENTS: SEE APPL # M156676