NYC Department of Buildings | ||
Electrical Application Details for App #: M074725 |
Premises: 454 9 AVENUE MANHATTAN | BIN: 1082250 Block: 759 Lot: 1 |
Printable (PDF) version of this Permit |
Filed: | 454 9 AV | Census Tract: 111 | Health Area: 5500 | |
BSMT FOR AP 15 | Admin Area: M - MANHATTAN | Inspection Area: Q | ||
NEW YORK, NY 10018 | Community Board: 104 | |||
DOB Cross Street(s): WEST 35 STREET, WEST 36 STREET | |||
Status: N - NO ACCESS 05/13/1991 | |||
Request Type: A - APPLICATION | eFiled: NO | ||
Application Entered: 11/02/1990 | Job Start Date: 10/22/1990 | ||
Last Change: 03/05/2003 | Job End Date: 10/26/1990 |
Appointment Status: | |||
Last Inspection By: ROMANELLO, D. On 05/09/1991 | |||
Field Disp: N - NO ACCESS | |||
Energize Recommendation: | |||
Objection Disposition: |
License #: | 010582 | Licensee Name: | ASTLEY G LEE | |
Firm: | 001747 | Firm Name: | LLEWELLYN ELECTRIC CORP. | |
Firm Phone: | 718-291-9338 | Firm Address: | 106-57 GUY-R-BREWER BLVD JAMAICA NY 11433 |
Work Started or Filed by Others: NO | ||||||||
Work Category: R - REHABILITATION | Work To Be Done:
1 - SERVICE WORK/NOTIFY UTILITY |
Total Fee: $16.00 | ||||||
Other Work: | ||||||||
Work Related to a New or Amended Certificate of Occupancy: NO | ||||||||
This Job Regulated by the NYC Energy Conservation Code: |
Building Used As: C - Three Family | |||||||
Special Cert Approval: | |||||||
Advisory Board Approval: | |||||||
Owner / Occup: | BRIAN DINNIGAS | ||||||
Authorized Representative: | |||||||
Relationship To Owner: |
|
Floor | Apt. | Number Of Outlets | No. Of Fixtures |
Motors / Generators | Heaters | Transformers | ||||||
Fixt | Receptacles | Switch | Num | Total HP KW | Num | Total KW | Num | Total KVA | ||||
ATT | A/C | |||||||||||
Buildings Total | ||||||||||||
Total Units : 0 units |
Signs: | Field Connect: | 0 | Field Inspect: | 0 | Tags: |
Meter Request to Utility | #3-Wire | 1 | #4-Wire | 0 | #10-Wire | 0 | |
Existing Meters | 0 | + New Meters | 0 | - Removed Meters | 0 | = Total Meters | 0 |
Power Auth Flag: | R - REQUESTED | Objection Flag: | |
Power Requested: | 11/02/1990 | Notice: | |
Power Issued: | 11/02/1990 | Response: |
Follow-Up: | |||
Wires Comments: INSPECTED WORK DONE BY OTHERS INSTALL 1-3W MTR FOR APT 15 NOT RESPON | |||
Contractor's Comments: |
|
INSP ID |
FIELD DATE |
DISP DATE |
INSP ID |
FLD DISP |
OBJ DISP |
ENRG REC |
TIME INSP |
REINSP DATE |
NEW OBJ |
APPT FLAG |
(1) | 05/09/1991 | 05/13/1991 | DR1 | N | (20) | (0) | ||||
INSPECTION COMMENTS: | No Inspection Comments For This Application |