BIS Menu  |  After Hours Variance Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M073471
Premises: 18 EAST 13 STREET MANHATTAN BIN: 1009379     Block: 570   Lot: 14
   

Filed: 18 E 13 ST Census Tract:   61 Health Area:  5700
227 NONE Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10003 Community Board:   102
DOB Cross Street(s):    5 AVENUE,    UNIVERSITY PLACE
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 02/06/2002
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/02/1990 Job Start Date:   10/15/1990
Last Change:   02/06/2002 Job End Date:   10/31/1990
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     01/30/2002      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010122 Licensee Name: E COHEN
Firm: 000390 Firm Name: DAVE ELECTRIC, INC.
Firm Phone: 718-788-0520  Firm Address: 1908 CONEY ISLAND AVE. BROOKLYN NY 11230 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $258.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: VILLAGE COPIER
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  1  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 15  20  10                    
Total Units : 45 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   NONE Contact Phone:   212/924-3456

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 9 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 10/02/1990 Notice: C - CALL TO OFFICE 06/13/1994
Power Issued: 10/02/1990 Response: A - SET UP APPOINTMENT 06/29/1993

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M073471
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/07/1990 11/13/1990 MIR J G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 06/27/1991 07/09/1991 JNU V G (45) (10)
INSPECTION COMMENTS: /
 
(3) 05/25/1993 06/07/1993 JNU H X G (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 07/28/1993 08/04/1993 KIW H X G (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 08/24/1993 09/01/1993 JNU H X G (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 09/13/1993 09/30/1993 IA1 P (60) (0)
INSPECTION COMMENTS: /
 
(8) 01/28/1994 02/16/1994 JNU Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 03/01/1994 03/10/1994 JNU H Y G (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 06/07/1994 06/13/1994 JNU H X G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 01/30/2002 02/06/2002 SVJ C R E (60) (0) Y
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.