BIS Menu  |  Applications  |  Property Profile  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M063441
Premises: 310 EAST 113 STREET MANHATTAN BIN: 1081095     Block: 1684   Lot: 1
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 310 E 113 ST Census Tract:   180 Health Area:  2100
BLDG NO 10 Admin Area:   M - MANHATTAN Inspection Area:   H
NEW YORK, NY 10029 Community Board:   111
DOB Cross Street(s):    2 AVENUE,    PEDESTRIAN PATH
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   02/22/1990 Job Start Date:   01/28/1990
Last Change:   08/22/2025 Job End Date:   06/10/1990
Appointment Status:   
Last Inspection By:   IVEY, A.       On     10/13/1994      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  X - NOT REMOVED

License #: 009476 Licensee Name: G RIGAS
Firm: 000560 Firm Name: G & R ELECTRIC CO. INC.
Firm Phone: 718-230-0500  Firm Address: 237 FOURTH AVE. BROOKLYN NY 11215 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $1,578.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: NYC HOUSING AUTHORITY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  3  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  4  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  4  
B. Over #2 to 1/0  2  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  4  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  54  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  2  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   212    108  159                
Total Units : 479 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 1
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 09/19/1990 Notice: C - CALL TO OFFICE 10/31/1994
Power Issued: 09/19/1990 Response: R - REINSPECTION 12/20/1993

Follow-Up:
Contractor's Comments:  CONTRACT NO EL88-4051 CIAP

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M063441
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 11/10/1993 12/01/1993 IA1 A G (45) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/07/1994 10/22/1994 GO1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/13/1994 10/31/1994 IA1 H X G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/02/1994 12/20/1994 GO1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 12/30/1994 01/23/1995 GO1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 11/15/1996 04/07/1997 GO1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Applications  |  Property Profile  |  Electrical Inspection Work Order  |  Back