Premises: 52 WATTS STREET MANHATTAN BIN: 1007123     Block: 477   Lot: 68
   
Application Completed and Certified

Filed: 52-54 WATTS ST Census Tract:   51 Health Area:  6800
2ND FL & BSMT Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10013 Community Board:   102
DOB Cross Street(s):   AVENUE OF THE AMERICAS,    VARICK STREET
Status:   C - JOB IS SIGNED OFF 12/17/1993
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   06/22/1988 Job Start Date:   08/19/1988
Last Change:   06/29/1993 Job End Date:   08/25/1988
Appointment Status:   
Last Inspection By:   FRANCES, W.       On     06/17/1993      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 008550 Licensee Name: H WARREN
Firm: 001511 Firm Name: WARREN ELECTRIC CO.
Firm Phone: 212-929-2936  Firm Address: 257 WEST 19TH STREET NEW YORK NY 10011 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $397.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   F - Factory
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ANDREW J HOMAR
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  1  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  1  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 12/16/1988 Notice: C - CALL TO OFFICE 08/20/1990
Power Issued: Response: S - SCHEDULE C. T. O 08/07/1990

Follow-Up: X - FILED APPL,NOW CLOSED 12/16/1988
Wires Comments: TEMP FOR 7 JAW METER
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M038817
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/07/1988 06/22/1988 WC1 W (20) (2)
INSPECTION COMMENTS: 3 400A SER SW SERV ENTRANCE COND & EEDER 2FL 225A 30 PNL SUB FD BRAN CH CKT
 
(6) 11/09/1988 11/29/1988 WC1 F (1) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 09/01/1989 09/19/1989 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 09/29/1989 10/17/1989 HVJ Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 11/10/1989 12/01/1989 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 12/22/1989 01/16/1990 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 02/16/1990 03/06/1990 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(12) 04/13/1990 05/01/1990 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(13) 05/31/1990 06/11/1990 KIW N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(14) 07/17/1990 07/19/1990 KIW H X E (55) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(16) 01/17/1992 02/26/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(17) 02/28/1992 03/25/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(18) 03/27/1992 04/21/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(19) 04/24/1992 05/14/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(20) 05/22/1992 06/11/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(21) 06/19/1992 07/14/1992 PB1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(22) 07/24/1992 08/06/1992 PB1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(23) 10/14/1992 10/21/1992 PB1 N (25) (0)
INSPECTION COMMENTS: LEFT CARD
 
(24) 12/11/1992 12/21/1992 PB1 H Y G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(25) 05/07/1993 05/26/1993 FW1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(26) 06/17/1993 06/29/1993 FW1 C R E (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application