BIS Menu  |  Applications  |  Elev. Device Details  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M038092
Premises: 1621 LEXINGTON AVENUE MANHATTAN BIN: 1051884     Block: 1630   Lot: 21
   
Application Completed and Certified

Filed: 1621 LEXINGTON AV Census Tract:   166 Health Area:  2810
BSMT Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10029 Community Board:   111
DOB Cross Street(s):   EAST 102 STREET,    EAST 103 STREET
Status:   C - JOB IS SIGNED OFF 06/13/1989
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   06/07/1988 Job Start Date:   05/08/1988
Last Change:   06/06/1989 Job End Date:   05/30/1988
Appointment Status:   
Last Inspection By:   ROMANELLO, D.       On     05/15/1989      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 010515 Licensee Name: JOSEPH BONURA
Firm: 001690 Firm Name: KEYSTONE ELECTRIC INC.
Firm Phone: 718-832-4642  Firm Address: 218 29TH STREET BROOKLYN NY 11232 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
8 - BOILER/BURNER WIRING
Total Fee:  $17.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: RAHBAR
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  1  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Wires Comments: BOILER WIRING ONLY
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M038092
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/29/1988 07/01/1988 DR1 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 12/27/1988 01/03/1989 DR1 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 03/15/1989 03/22/1989 DR1 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 05/15/1989 06/06/1989 DR1 C (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.