BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M037526
Premises: 1501 1 AVENUE MANHATTAN BIN: 1045254     Block: 1453   Lot: 25
   
Application Completed and Certified

Filed: 1501 1 AV Census Tract:   134 Health Area:  4200
BSMT Admin Area:   M - MANHATTAN Inspection Area:   K
NEW YORK, NY 10021 Community Board:   108
DOB Cross Street(s):   EAST 78 STREET,    EAST 79 STREET
Status:   C - JOB IS SIGNED OFF 06/08/1989
Request Type:   P - PICK-UP eFiled:   NO
Application Entered:   05/23/1988 Job Start Date:   09/07/1988
Last Change:   05/17/1989 Job End Date:   09/15/1988
Appointment Status:   
Last Inspection By:   BELEC, P       On     05/10/1989      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010140 Licensee Name: H ROSENBLAT
Firm: 000429 Firm Name: DIAL ELECTRIC CO.
Firm Phone: 212-728-3311  Firm Address: 20 56A STEINWAY STREET QUEENS NY 11105 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $29.00
Other Work:   REMOVE VIOLATION
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: RICHARD MCNALLY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                     
Total Units : 7 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   AFTERNOONS Contact Phone:   734-1412

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice:  08/17/1988
Power Issued: Response: F - FILED TO REMOVE OBJECTION 09/06/1988

Follow-Up: X - FILED APPL,NOW CLOSED 09/06/1988
Wires Comments: VIOLATION REMAINING NEW BX & INSTALLING EMT
Contractor's Comments:  ASS.AS PER KENNY TO PB1 FOR 890414 ON 890421

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M037526
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/12/1988 05/23/1988 GO1 W (20) (5)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/17/1988 08/25/1988 GO1 F (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 04/05/1989 04/07/1989 PB1 J Y (40) (0)
INSPECTION COMMENTS: NONE
 
(6) 05/10/1989 05/17/1989 PB1 C R (90) (0)
INSPECTION COMMENTS: N/C




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order