BIS Menu  |  Plumb. Inspections  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M018044
Premises: 54 WEST 13 STREET MANHATTAN BIN: 1080148     Block: 576   Lot: 14
   
Application Completed and Certified

Filed: 54 W 13 ST Census Tract:   63 Health Area:  5700
1FL Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10011 Community Board:   102
DOB Cross Street(s):    5 AVENUE,    AVENUE OF THE AMERICAS
Status:   C - JOB IS SIGNED OFF 02/10/1989
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/03/1987 Job Start Date:   03/30/1987
Last Change:   01/11/1989 Job End Date:   04/30/1987
Appointment Status:   
Last Inspection By:   NUTTING, J.       On     01/04/1989      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  R - REMOVED

License #: 010118 Licensee Name: ROBERT MARCHISOTTO
Firm: 000055 Firm Name: ACCU-GLO ELEC'L CORP.
Firm Phone: 718-729-1113  Firm Address: 38-26 30TH STREET L I C NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $58.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   Z - Other
Store / Other:   RESTURANT
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: MR KERTENZ
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  1  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 10  12    10                
Total Units : 37 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: R - OBJECTION(S) RESOL
Power Requested: Notice: C - CALL TO OFFICE 09/01/1988
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  * OWNER VIOL.-SEE # M017646

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M018044
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 06/02/1987 06/17/1987 SM1 A (75) (4)
INSPECTION COMMENTS: SEE COMMENTS
 
(2) 07/10/1987 07/27/1987 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 08/10/1987 08/18/1987 SM1 N (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 02/17/1988 02/24/1988 JNU N (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 03/30/1988 04/06/1988 JNU H X (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 06/21/1988 06/23/1988 JNU H X (30) (0)
INSPECTION COMMENTS: 3 C T O
 
(7) 08/30/1988 09/01/1988 JNU H X (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 11/11/1988 11/29/1988 JNU Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 01/04/1989 01/11/1989 JNU C R (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.