Electrical Application Details for App #: M016299
Premises: 192 BLEECKER STREET MANHATTAN BIN: 1008301     Block: 526   Lot: 23
   
Application Completed and Certified

Filed: 192 BLEECKER ST Census Tract:   65 Health Area:  5700
ROOF Admin Area:   M - MANHATTAN Inspection Area:   S
NEW YORK, NY 10012 Community Board:   102
DOB Cross Street(s):   MAC DOUGAL STREET,    AVENUE OF THE AMERICAS
Status:   C - JOB IS SIGNED OFF 09/07/1994
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   03/04/1987 Job Start Date:   02/25/1987
Last Change:   09/07/1994 Job End Date:   02/27/1987
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     08/23/1994      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  

License #: 009927 Licensee Name: M BOJSIUK
Firm: 001224 Firm Name: RAYPALS ELEC'L CORP.
Firm Phone: 718-834-0420  Firm Address: 200 SACKETT STREET BROOKLYN NY 11231 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
9 - OTHER
Total Fee:  $23.00
Other Work:   WIRING OF 2HP EXAUST FAN
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   K - Store
Store / Other:   RESTAURANT
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: ARLECCHINO RETAURANT
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  1  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                       
Total Units : 2 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: R - REQUESTED Objection Flag:
Power Requested: 04/15/1987 Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  WIRING OF 2HP EXHAUST FAN (ROOF)

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M016299
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 03/31/1987 04/03/1987 FCO N (10) (0)
INSPECTION COMMENTS: STREET LOCKED. OPEN AT NIGHT?
 
(2) 08/23/1994 09/07/1994 X01 C G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application