BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M010661
Premises: 209 EAST 5 STREET MANHATTAN BIN: 1076944     Block: 461   Lot: 52
   
Application Completed and Certified

Filed: 209 E 5 ST Census Tract:   38 Health Area:  6500
APTS. 1 AND 7 Admin Area:   M - MANHATTAN Inspection Area:   T
NEW YORK, NY 10003 Community Board:   103
DOB Cross Street(s):   COOPER SQUARE,    2 AVENUE
Status:   C - JOB IS SIGNED OFF 12/26/1995
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   10/31/1986 Job Start Date:   10/29/1986
Last Change:   05/05/1995 Job End Date:   11/15/1986
Appointment Status:   
Last Inspection By:   PRIVATE AGENCY       On     04/20/1995      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  R - REMOVED

License #: 009286 Licensee Name: JOSESPH GAROFOLO
Firm: 000569 Firm Name: GARY ELECTRIC CO.
Firm Phone: 212-861-9226  Firm Address: 223 EAST 85TH STREET NEW YORK NY 10028 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $56.75
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: D KUPERBERG
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 12  26  12  12                
Total Units : 65 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 10/31/1986 Notice: 1 - FIRST NOTICE 09/01/1988
Power Issued: 10/31/1986 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: PHONE # OR7-6233
Contractor's Comments:  2 AND 3 AV

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M010661
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/11/1986 12/22/1986 SM1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 11/06/1987 11/10/1987 KIW P (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 02/25/1988 03/11/1988 DH2 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 04/15/1988 05/02/1988 DH2 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 07/13/1988 07/19/1988 DH2 N (15) (0)
INSPECTION COMMENTS: LEFT CARD FOR APT
 
(6) 08/29/1988 09/01/1988 DH2 V E (40) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 04/10/1989 04/19/1989 DH2 N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 05/12/1989 06/14/1989 DH2 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 04/13/1990 05/23/1990 DR1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 07/06/1990 07/25/1990 DR1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 09/13/1990 10/01/1990 DR1 N (10) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(12) 08/02/1991 08/27/1991 HVJ Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(13) 09/03/1991 09/05/1991 HVJ N (15) (0)
INSPECTION COMMENTS: NONE
 
(14) 07/28/1992 08/06/1992 KIW N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(15) 01/15/1993 02/01/1993 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(16) 02/18/1993 02/24/1993 KIW N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(17) 07/16/1993 08/03/1993 KIW Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(18) 08/17/1993 08/23/1993 KIW N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(19) 10/14/1993 10/20/1993 KIW N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(20) 04/20/1995 05/05/1995 X01 C R G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.