BIS Menu  |  Pre-BIS PA CO Query By Bin  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M007436
Premises: 1626 3 AVENUE MANHATTAN BIN: 1078533     Block: 1520   Lot: 38
   
Application Completed and Certified

Filed: 1626 3 AV Census Tract:   158.01 Health Area:  2820
BSMNT Admin Area:   M - MANHATTAN Inspection Area:   J
NEW YORK, NY 10128 Community Board:   108
DOB Cross Street(s):   EAST 91 STREET,    EAST 92 STREET
Status:   C - JOB IS SIGNED OFF 11/17/1986
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/22/1986 Job Start Date:   08/25/1986
Last Change:   11/05/1986 Job End Date:   09/05/1986
Appointment Status:   
Last Inspection By:   NUTTING, J.       On     10/29/1986      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  

License #: 010555 Licensee Name: K LLEWELLYN
Firm: 001747 Firm Name: LLEWELLYN ELECTRIC CORP.
Firm Phone: 718-291-9338  Firm Address: 106-57 GUY-R-BREWER BLVD JAMAICA NY 11433 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $65.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: EL-KAM REALITY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  1  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 9 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag:
Power Requested: 09/11/1986 Notice:  
Power Issued: 09/11/1986 Response:  

Follow-Up: K - (CLOSED)
Wires Comments: CHECK APPLICATION #M004368 FOR 2ADDITIONAL METERS THIS 200AMP 3/4WIR
Contractor's Comments:  BETWEEN 91ST 92ND ST

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M007436
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/29/1986 10/07/1986 JNU N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/29/1986 11/05/1986 JNU C E (30) (0)
INSPECTION COMMENTS: SEE COMMENTS




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.