BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M006493
Premises: 20 RUTGERS STREET MANHATTAN BIN: 1087057     Block: 273   Lot: 27
   
Application Completed and Certified

Filed: 142 HENRY ST Census Tract:   6 Health Area:  7800
BSMT SERV Admin Area:   M - MANHATTAN Inspection Area:   V
NEW YORK, NY 10002 Community Board:   103
DOB Cross Street(s):   PIKE STREET,    RUTGERS STREET
Status:   C - JOB IS SIGNED OFF 09/22/1987
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/05/1986 Job Start Date:   07/29/1986
Last Change:   09/22/1987 Job End Date:   08/15/1986
Appointment Status:   
Last Inspection By:   WONG, K.       On     09/16/1987      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010482 Licensee Name: HARVEY ISAACMAN
Firm: 001626 Firm Name: HARVEY ISAACMAN ELEC. INC
Firm Phone: 718-857-9156  Firm Address: 35 ALLEN STREET NEW YORK NY 10002 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
5 - FIRE DAMAGE
9 - OTHER
Total Fee:  $317.00
Other Work:   INSTALLA.OF SERV.DUE TO FIRE RECONN.EX.LOA
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: NOT GIVEN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  2  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  4  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  2  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   M-F 9-5 Contact Phone:   212 925 1417

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 1 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 08/05/1986 Notice: C - CALL TO OFFICE 03/18/1987
Power Issued: 08/05/1986 Response: R - REINSPECTION 10/29/1986

Follow-Up: K - (CLOSED)
Wires Comments: SERV.SW & RECONN.OF EX.LOADS WITH INSTALLA.OF NEW END BOX WITH CREDI
Contractor's Comments:  END BOX 1-3/0 200 AMP SW 1-150AMP SERV.SW BASE

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M006493
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/02/1986 09/04/1986 KIW J G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/02/1986 09/05/1986 KIW J G (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/14/1986 10/21/1986 KIW A G (45) (3)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 11/17/1986 11/24/1986 KIW H Y (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 03/10/1987 03/18/1987 KIW H X (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 05/01/1987 05/19/1987 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 09/16/1987 09/22/1987 KIW C R E (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order