Electrical Application Details for App #: M006411
Premises: 14 BEDFORD STREET MANHATTAN BIN: 1008347     Block: 527   Lot: 7
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 14-16 BEDFORD ST Census Tract:   67 Health Area:  6400
2,3,& 4TH FL Admin Area:   M - MANHATTAN Inspection Area:   R
NEW YORK, NY 10014 Community Board:   102
DOB Cross Street(s):   AVENUE OF THE AMERICAS,    DOWNING STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   08/04/1986 Job Start Date:   07/15/1986
Last Change:   08/22/2025 Job End Date:   08/15/1986
Appointment Status:   
Last Inspection By:   WEISBART, F.       On     01/30/1995      
Field Disp:   H - NO PROGRESS ON JOB
Energize Recommendation:  G - NO COMMENT
Objection Disposition:  X - NOT REMOVED

License #: 010199 Licensee Name: J BOFFA
Firm: 001811 Firm Name: J. BOFFA ELECTRIC CORP.
Firm Phone: 718-585-1830  Firm Address: 187 WILLOW AVENUE BRONX NY 10454 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
6 - GENERAL WIRING
Total Fee:  $69.25
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: A.W.CLARK MGT CORP
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  1  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  1  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  2  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  2  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total 25                  
Total Units : 43 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

Access:   CALL FOR ENTRY Contact Phone:   691-2323

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 2 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: I - ISSUED Objection Flag: V - OBJECTION(S) EXIST
Power Requested: 08/04/1986 Notice: C - CALL TO OFFICE 02/08/1995
Power Issued: 08/04/1986 Response:  

Follow-Up:
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M006411
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 09/10/1986 09/12/1986 NC1 J G (60) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 10/24/1986 10/28/1986 NC1 N (20) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 01/23/1987 02/09/1987 NC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 08/26/1987 08/28/1987 JNU N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 12/04/1987 12/17/1987 MIR N (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(6) 08/05/1988 08/23/1988 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 09/16/1988 10/03/1988 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 10/28/1988 11/21/1988 SM1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 11/22/1988 12/01/1988 DH1 N (11) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(10) 12/23/1988 01/11/1989 DH1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 05/25/1989 06/07/1989 WMK P (35) (0)
INSPECTION COMMENTS: NO ACCESS APT12 & BSMT LC WITH TENANT IN APT 3
 
(12) 12/21/1989 01/05/1990 DH2 N (25) (0)
INSPECTION COMMENTS: NONE
 
(13) 03/30/1990 04/24/1990 SL1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(14) 02/04/1991 02/11/1991 DR1 N (5) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(15) 07/24/1991 07/29/1991 DR1 N (30) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(16) 02/17/1993 02/24/1993 JNU N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(17) 05/24/1993 06/11/1993 GO1 V G (20) (4)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(18) 01/30/1995 02/08/1995 FWE H X (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application