BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: M000880
Premises: 309 SPRING STREET MANHATTAN BIN: 1010358     Block: 597   Lot: 1
  Printable (PDF) version of this Permit  

DOB NOW: Inspections


Filed: 515 GREENWICH ST Census Tract:   53 Health Area:  6800
169465 2 & 3 Admin Area:   M - MANHATTAN Inspection Area:   U
NEW YORK, NY 10013 Community Board:   102
DOB Cross Street(s):   SPRING STREET,    VANDAM STREET
Status:   E - ABANDONED 08/22/2025
Request Type:   C - COMPLAINT eFiled:   NO
Application Entered:   04/28/1986 Job Start Date:   05/11/2001
Last Change:   08/22/2025 Job End Date:   08/11/2001
Appointment Status:   
Last Inspection By:   SEVERIANO JOHN       On     07/01/2002      
Field Disp:   P - PARTIAL NO ACCESS
Energize Recommendation:  
Objection Disposition:  

License #: 009615 Licensee Name: ROBERT COVELLO
Firm: 001205 Firm Name: ROBERT S. COVELLO
Firm Phone: 718-786-7390  Firm Address: 51-20 35TH STREET L.I.C. NY 11101 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
9 - OTHER
Total Fee:  $537.25
Other Work:   VIOLATION REMOVAL
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   O - Office Bldg
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup: OSSA PROPERTIES
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  9  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  5  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   314    62  203                
Total Units : 579 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag: V - OBJECTION(S) EXIST
Power Requested: Notice:  05/21/1986
Power Issued: Response: F - FILED TO REMOVE OBJECTION 05/17/2001

Follow-Up: F - FILED TO REMOVE OBJECTION 05/17/2001
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: M000880
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 05/09/1986 05/21/1986 FCO W (50) (1)
INSPECTION COMMENTS: VIO ISSUED TO OWNER NO APP ON FILE FOR ELECT WORK 3-NO APP ON FILE FOR INSTALLATION OF NEW PNLS, SUBFEEDERS, BRANCH CKT WIRING FOR RECPTS, SW FIXT OUT AND FIXTURES
 
(2) 07/01/2002 07/05/2002 SVJ P (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 08/30/2002 12/03/2002 SVJ Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.