BIS Menu  |  Electrical Inspection Work Order   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: K28019
Premises: 944 42 STREET BROOKLYN BIN: 3135788     Block: 5595   Lot: 19
   
Application Completed and Certified

Filed: 944 42 ST Census Tract:   112 Health Area:  6700
BASEMENT Admin Area:   B - BROOKLYN Inspection Area:   J
BROOKLYN, NY 11219 Community Board:   312
DOB Cross Street(s):    9 AVENUE,    10 AVENUE
Status:   C - JOB IS SIGNED OFF 04/08/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   01/02/1986 Job Start Date:   11/24/1985
Last Change:   03/08/1988 Job End Date:   12/10/1985
Appointment Status:   
Last Inspection By:   ROSE, M.       On     03/02/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 008807 Licensee Name: H TEITLER
Firm: 000579 Firm Name: GEORGE DIAKOS EL. CONT. C
Firm Phone: 212-833-1713  Firm Address: 923 71ST STREET BROOKLYN NY 11228 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $1,141.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 944 42 ST REALTY
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  42  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  42  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total   42                      
Total Units : 42 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 42 #4-Wire 1 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 02/02/1988 Notice:  02/02/1988
Power Issued: 02/04/1987 Response: R - REINSPECTION 02/03/1988

Follow-Up: K - (CLOSED)
Wires Comments: 42 METER SERVICE 3W 1 4W 200A 3/0 METER 42 OUTLETS
Contractor's Comments:  E 500

 
Inspection Details
 

INSPECTION FOR APPLICATION #: K28019
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 02/03/1986 LS1 J D (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 09/05/1986 09/22/1986 NEI Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/28/1986 10/31/1986 NEI A B (35) (1)
INSPECTION COMMENTS: SUPT C 11 NEUTRAL BAR IS NOT BONDED TO ENCLOSURE B30970B
 
(4) 01/09/1987 01/26/1987 NEI Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 03/24/1987 03/27/1987 SC1 A R B (1) (3)
INSPECTION COMMENTS: NONE
 
(6) 06/24/1987 07/08/1987 SC1 A R G (45) (2)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 09/04/1987 09/18/1987 SC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 10/16/1987 10/30/1987 SC1 Z (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 11/18/1987 11/25/1987 SC1 H X B (90) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(11) 12/28/1987 01/13/1988 MF1 N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(12) 01/26/1988 02/02/1988 MF1 H X B (40) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(13) 03/02/1988 03/08/1988 MX1 C R E (25) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Electrical Inspection Work Order