BIS Menu  |  Property Permits  |  Electrical Inspection Work Order  |  Back   FAQs  |  Glossary   
DOB Logo - Link to Homepage NYC.gov Logo - Link to Homepage
NYC Department of Buildings
Electrical Application Details for App #: K17841
Premises: 436 STERLING PLACE BROOKLYN BIN: 3029396     Block: 1173   Lot: 41
   

Filed: 436 STERLING PL Census Tract:   207 Health Area:  4500
20 APTS Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11238 Community Board:   308
DOB Cross Street(s):   UNDERHILL AVENUE,    WASHINGTON AVENUE
Status:   C - SIGNOFF IS AWAITING FEE PAYMENT 12/12/1988
Request Type:   A - APPLICATION eFiled:   NO
Application Entered:   04/25/1985 Job Start Date:   03/28/1985
Last Change:   12/12/1988 Job End Date:   04/12/1985
Appointment Status:   
Last Inspection By:   ROSE, M.       On     10/26/1988      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  E - ISSUE POWER AUTH
Objection Disposition:  R - REMOVED

License #: 010226 Licensee Name: W MALDONADO
Firm: 000926 Firm Name: MAL-REY ELEC. & AIR COND.
Firm Phone: 212-842-6415  Firm Address: 915 CASTLE HILL AVENUE BRONX NY 10462 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
1 - SERVICE WORK/NOTIFY UTILITY
Total Fee:  $524.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:  
Building Used As:   C - Three Family
Special Cert Approval:  
Advisory Board Approval:  
Owner / Occup:
Owner Business Name: 436 STERLING PL ASSOC
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  1  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  1  
D. Over 250 MCM  0  
SUB FEEDERS (EACH SET)  
A. Up to #2 CONDUCTOR  21  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  21  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
Buildings Total                         
Total Units : 0 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 21 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: K - CANCELLED Objection Flag: R - OBJECTION(S) RESOL
Power Requested: 08/19/1986 Notice: C - CALL TO OFFICE 12/24/1986
Power Issued: 05/22/1986 Response: R - REINSPECTION 09/26/1986

Follow-Up: K - (CLOSED)
Wires Comments: 20 APTS 3 OUTLETS PER APT 350 MCM SUB FED 1 400A SVCE EQ 21 3 METER
Contractor's Comments:  E 500

 
Inspection Details
 

INSPECTION FOR APPLICATION #: K17841
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/04/1985 LDM N (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(2) 08/06/1986 08/19/1986 WMK A B (50) (3)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(3) 10/22/1986 10/24/1986 WMK N (0) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(4) 12/19/1986 12/24/1986 WMK H X (45) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(5) 09/15/1987 09/17/1987 JB1 N (35) (0)
INSPECTION COMMENTS: LEFT CARD
 
(6) 09/26/1987 09/29/1987 JB1 N (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(7) 10/10/1987 10/15/1987 KIW N (35) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(8) 06/01/1988 06/13/1988 HVJ N (15) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application
 
(9) 10/26/1988 12/12/1988 MX1 C R E (50) (0)
INSPECTION COMMENTS: No Inspection Comments For This Application




If you have any questions please review these Frequently Asked Questions, the Glossary, or call the 311 Citizen Service Center by dialing 311 or (212) NEW YORK outside of New York City.


BIS Menu  |  Property Permits  |  Electrical Inspection Work Order  |  Back