Electrical Application Details for App #: B436186
Premises: 37 CLIFTON PLACE BROOKLYN BIN: 3055552     Block: 1947   Lot: 35
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 37 CLIFTON PL Census Tract:   197 Health Area:  1200
2FL Admin Area:   B - BROOKLYN Inspection Area:   D
BROOKLYN, NY 11238 Community Board:   302
DOB Cross Street(s):   ST JAMES PLACE,    GRAND AVENUE
Status:   C - JOB IS SIGNED OFF 12/14/2017
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/24/2017 3:53 PM
Application Entered:   10/24/2017 Job Start Date:   10/25/2017
Last Change:   12/14/2017 Job End Date:   11/23/2017
Appointment Status:   
Last Inspection By:   NAJI PHILLIIPS       On     12/14/2017      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 011511 Licensee Name: EUSEBIO E MCQUEEN
Firm: 002982 Firm Name: RM ELECTRIC CO., INC.
Firm Phone: 718-272-0065  Firm Address: 240 KENT AVE, SUITE KB/22C BROOKLYN NY 11249 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $86.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   B - Two Family
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup: TONY MARTIN
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  1  36 CKT BREAKER PANEL
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
MZ1                       
MZ2                 
MZ3                 
Buildings Total 12  10    10  12                
Total Units : 44 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  PARCIAL WIRING KITCHEN AND BATHROOM ONLY

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B436186
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 12/14/2017 12/14/2017 NJP C (25) (0) Y
INSPECTION COMMENTS: THE JOB IS OK.