Electrical Application Details for App #: B435239
Premises: 2813 FARRAGUT ROAD BROOKLYN BIN: 3120967     Block: 5230   Lot: 3
   

DOB NOW: Inspections

Application Completed and Certified

Filed: 2811 FARRAGUT RD Census Tract:   788 Health Area:  7410
BASEMENT AND 1ST FLOOR Admin Area:   B - BROOKLYN Inspection Area:   K
BROOKLYN, NY 11210 Community Board:   314
DOB Cross Street(s):   EAST 28 STREET,    EAST 29 STREET
Status:   C - JOB IS SIGNED OFF 08/04/2022 Balance Paid By Owner
Request Type:   A - APPLICATION eFiled:   YES Permit Issued:  10/03/2017 11:52 AM
Application Entered:   10/03/2017 Job Start Date:   10/03/2017
Last Change:   08/04/2022 Job End Date:   11/06/2017
Appointment Status:   
Last Inspection By:   DHANESHWAR BISSOON       On     08/04/2022      
Field Disp:   C - INSPECTION PASSED
Energize Recommendation:  
Objection Disposition:  

License #: 009747 Licensee Name: MELVYN ZWEBNER
Firm: 002640 Firm Name: ILLUMINOUS ELECTRIC CORP.
Firm Phone: 718-431-1605  Firm Address: 1425 37TH STREET BROOKLYN NY 11218 

Work Started or Filed by Others: NO
Work Category:   R - REHABILITATION Work To Be Done:  
6 - GENERAL WIRING
Total Fee:  $74.00
Other Work:   
Work Related to a New or Amended Certificate of Occupancy:   NO
This Job Regulated by the NYC Energy Conservation Code:   No
Building Used As:   W - School
Special Cert Approval:  
Advisory Board Approval:   NOT APPLICABLE
Owner / Occup:
Owner Business Name: BUMBLE BEES R US
Authorized Representative:   
Relationship To Owner:   


WORK DESCRIPTION
BUILDING OVERVIEW Are Feeders Being Installed? :   No
(If feeders are being installed, provide a wiring diagram and calculations at the time of inspection)
Building Overview Work Items QUANTITY DESCRIPTION
SERVICE SWITCHES  
A. Up to 100 AMPS  0  
B. 101 Up to 200 AMPS  0  
C. 201 Up to 600 AMPS  0  
D. 601 Up to 1200 AMPS  0  
E. Over 1200 AMPS  0  
SER. ENT. & FDR COND (EACH SET)  
A. Up to #2 CONDUCTOR  0  
B. Over #2 to 1/0  0  
C. Over 1/0 to 250 MCM  0  
D. Over 250 MCM  0  
PANELS  
A. 1 Phase Up to 20-1 or 10-2 Pole Brkrs  0  
B. 1 Phase Over to 21-1 or 10-2 Pole Brkrs  0  
C. 3 Phase Up to 225 AMPS  0  
D. 3 Phase Over 225 AMPS  0  
ELEVATORS / ESCALATORS / MATERIAL LIFTS  
A. Total No. of Elevators / Escalators / Material Lifts  0  
B. Each Additional 10 Floors Or Less  0  
BOILER CONTROLS  0  

FLOOR DESCRIPTIONS
Floor Apt. Number Of Outlets No. Of
Fixtures
Motors / Generators Heaters Transformers
Fixt Receptacles Switch Num Total HP KW Num Total KW Num Total KVA
ATT A/C
BAS    25  25    25               
001    25  21    25               
Buildings Total 50  46    50                  
Total Units : 146 units   

Signs: Field Connect: 0 Field Inspect: 0 Tags:

SERVICE / METER EQUIPMENT
Meter Request to Utility #3-Wire 0 #4-Wire 0 #10-Wire 0
Existing Meters 0 + New Meters 0 - Removed Meters 0 = Total Meters 0

Power Auth Flag: Objection Flag:
Power Requested: Notice:  
Power Issued: Response:  

Follow-Up: K - (CLOSED)
Contractor's Comments:  

 
Inspection Details
 

INSPECTION FOR APPLICATION #: B435239
INSP
ID
FIELD
DATE
DISP
DATE
INSP
ID
FLD
DISP
OBJ
DISP
ENRG
REC
TIME
INSP
REINSP
DATE
NEW
OBJ
APPT
FLAG
 
(1) 07/21/2022 07/21/2022 SGY N (20) (0) Y
INSPECTION COMMENTS: NO ACCESS
 
(2) 08/04/2022 08/04/2022 DWB C (46) (0) Y
INSPECTION COMMENTS: NEIL GROSS- INSPECTION COMPLETE,